3-71
Catalyst 6500 Series Switches Installation Guide
OL-5781-08
Chapter 3 Installing the Switch
Attaching the Interface Cables
To install and cable a XENPAK transceiver uplink port, follow these steps:
Step 1
Attach an ESD-preventive wrist strap to your wrist and to the ESD ground connector or to a properly
grounded bare metal surface.
Step 2
Loosen the two screws that secure the uplink port cover plate to the supervisor engine faceplate and
remove the cover plate. Save the cover plate for future use.
Step 3
Remove the XENPAK transceiver from its protective packaging.
Note
Do not remove the optical bore dust plugs until you are directed to do so later in the procedure.
Step 4
Check the label on the XENPAK transceiver body to verify that you have the correct model for your
network.
Step 5
Find the transmit (TX) and receive (RX) markings that identify the top side of the XENPAK transceiver.
Note
On some XENPAK transceivers, the TX and RX marking might be replaced by arrows pointing
from the XENPAK transceiver connector (transmit direction or TX) and toward the connector
(receive direction or RX).
Step 6
Position the XENPAK transceiver in front of the uplink port opening and slide the XENPAK transceiver
into the opening until you determine that the XENPAK transceiver faceplate is in contact with the
supervisor engine faceplate. (See
Figure 3-40
.) This step ensures that the XENPAK transceiver is fully
seated in the supervisor engine socket.
Figure 3-40
Installing a XENPAK Transceiver
99377
RX
TX
LINK
Captive installation
screws
Optical bore
dust plugs