4-10
Cisco 6260 Hardware Installation Guide
OL-2365-02
Chapter 4 Installing a Cisco 6260 Without a POTS Splitter Configuration
Installation Procedures
Figure 4-5
Strip and Square Off Power and Ground Wires
Warning
Remove the covering from exactly the specified length of each power wire. If you strip too much of
the covering, exposed wire protruding from the terminal block will create an electrical hazard. If you
strip too little of the covering, the wire may not make a good contact with the terminal, or it may not
be held securely in place in the terminal block.
Step 4
Use a flat-head screwdriver to turn all three screws on the terminal block counterclockwise to open the
terminal connectors: + (positive), – (negative), and ground. This step ensures that the correct opening is
presented for the wires, as shown in
Figure 4-6
.
Figure 4-6
Positioning the Power and Ground Terminals to Accept Wires
26689
0.43 in.
(11 mm)
26693
INPUT OK
OUT F
AIL
FAN TRA
Y 1
FANTRA
Y 2
INPUT OK
OUT F
AIL
FAN TRA
Y 1
FANTRA
Y 2
Correct
terminal
position
(open)
Incorrect
terminal
position
(closed)