Rev Z
Page 50
11/28/2011
Copyright © 2011 by Cirus Controls, LLC. All Rights Reserved. No part of this material may be reproduced without the express
written permission of Cirus Controls LLC for each reproduction.
The
update rate
is how often the gate height is evaluated and if necessary, changed. This
prevents surging.
Automatic Trim Procedure: Press <PASS> on the up and down speed runs the automatic
calibration for the speed. Follow the on screen instructions:
The calibration routine runs the gate all the way down to minimum and then measures the gate to
make sure it's down. Then it runs the gate up for 2 seconds. It measures the gate to get the
distance travelled, and divides by 2, giving the speed in inches/sec (or cm/sec for metric mode).
Then it runs the gate up again for 2 seconds to get it enough room to do the down cal in case the
down speed is faster. It takes the top measurement, runs the gate down two seconds, and makes
the down reading. It will then ask you to confirm the setting.The auto gate is now ready to run.
Maximum output in “dump” mode functions in “automatic” and “no ground speed”
modes only, as no speed signal is present in manual mode