Rev Z
Page 41
11/28/2011
Copyright © 2011 by Cirus Controls, LLC. All Rights Reserved. No part of this material may be reproduced without the express
written permission of Cirus Controls LLC for each reproduction.
Note: units of measure here must match units of measure in master set up. If you are
changing from English to Metric units, you must start at the first setup step and be
consistent or calibration errors will occur;
g)
Pump max. Gal/minute:
enter the max output rating of your anti-ice system pump.
h)
Tier 1 Max GPM: Enter the maximum flow rate of the Tier 1 booms (in gallons per minute).
This setting is the point at which the Tier 2 –High Flow Booms turn on. See table below for
reference. Note: early versions of
SpreadSmart Rx
TM
named this function “Tier 2 GPM.”
The value entered is the same as Tier 1 max GPM.
i)
Tier 2 Max GPM. Enter the maximum flow rate of the Tier 2 booms (in gallons per minute).
This setting is the point at which the system turns both tiers on. Note: if you have answered
yes to “use single tier relay,” this question is not asked on the screen.
Earlier versions of
SpreadSmart Rx
TM
named this function as “Tier 1+ Tier 2 GPM.” The
value to enter is the same as the Tier 2 max GPM.
j)
Use s to return to the minimum trim line.
Anti-Ice Pump Trimming
VERIFY THAT FLUID IS PRESENT IN ANTI-ICE TANK BEFORE BEGINNING.
1)
Turn on all boom valve buttons (3),
2)
Press s to reach the “minimum trim” line. .
3)
Press “pass” to enter trim calibration.
4)
Enable at least one boom control valve button.
5)
Choose either automatic (requires flow meter) or manual (with or without flow meter)
calibration. The unit can automatically calibrate the trim settings using the sensor as
feedback or manually (faster for more experienced users), by selecting “manual”.
Automatic Anti-Ice Pump Trimming and Configuration
If you selected auto trimming, the unit automatically selects the trim levels using the flow meter
(sensor) as feedback.
1)
Step through the instructions using the pass button to begin trim calibration.
2)
Once initiating auto trimming, you have 10 seconds to raise the engine RPM.
3)
Hold RPM constant while unit is calibrating. This may take as much as two minutes.
(You may cancel the trim test at any time using the blast key.)
4)
Once the automatic trim calibration test is completed, the user is asked to “accept
calibration”. Select “Y” using the spinner control, and then press pass.
Trimming and Configuration is complete, select blast again to return to main menu.
WARNING
Potential for injury due to unexpected
operation of liquid spray system.
High-pre ssure liquid spray will cause
severe eye injury, with possible per-
manent loss of vi sion.
During initial startup and te sting, the
liquid system may start without warn-
ing.
Wear face and eye protection when
working with active high-pressure
spray system s.