Granular Material Flow Sensing:
when installed, the granular sensor is monitored by
SpreadSmart
TM
and warns the operator when material is
not
moving past the sensor.
Pressure Sensor Display:
when installed with the optional Large Format display, the
SpreadSmart
TM
system displays a hydraulic pressure reading from a pressure sensor installed in
the hydraulic system.
Installation:
the MDM is designed to be installed in the cab of the truck in close proximity to
the
SpreadSmart
TM
CPU.
1) Connect all cables:
DC 1000 - Multi-plex input cable; connect to MDM 400 module;
a) Hopper sensor
mplex connector 1;
b) Gate Height sensor
mplex connector 2;
c) Material Flow sensor
mplex connector 3;
d) Hydraulic pressure sensor
mplex connector 4;
DC 1001 and DC 1002 – sensor input cables. Choose for proper connection to sensors in use.
Plug into DC-1000 cable as shown above.
HH1001 -Cirus Bus Cable; connect to Bus port on MDM 400 and on
SpreadSmart
TM
CPU.
MK 1003 – Power cable, connect to 12v supply, ignition hot and battery ground;
Configuration
: Turn on
SpreadSmart
TM
and enter the configuration menu as before.
Select Trim/Cal and select MDM Module:
Enable Sensors installed in the truck using “anti-ice +/-” key to choose yes or no.
a)
Calibrate the Gate Height Sensor
Default Gate Height setting
: choose this opening size and always use this opening size for
material calibration steps. Use “anti-ice +/-” key to raise or lower this value (allowable range is
1.5 to 24 inches). Select “default gate height setting” and hit “pass.”