Rev Z
Page 28
11/28/2011
Copyright © 2011 by Cirus Controls, LLC. All Rights Reserved. No part of this material may be reproduced without the express
written permission of Cirus Controls LLC for each reproduction.
Granular Material
1)
Power down and then up, scroll down to Unload Mode and push “pass” to select;
2)
Verify that the media you wish to unload (granular) is on using the main button. The unload
mode operating screen is displayed and the rate defaults to 0% (The rate is displayed as a
percentage of full scale).
3)
Raise the % output to the desired level using the auger +/- toggle.
4)
Pressing pass in unload mode turns off dispensing.
5)
When unloading is complete, push blast and controller will return to the mode screen.
Anti-Ice Material
1.
Turn off boom valves on
SpreadSmart Rx
TM
.
2.
Power down and up, scroll down to Unload Mode and push “pass” to select;
3.
The unload mode operating screen is displayed and the rate defaults to 0% (The rate is
displayed as a percentage of full scale).
4.
Actuate one or more boom buttones.
5.
Raise the % output to the desired level using the anti-ice +/- toggle.
6.
(The truck must be stopped in order to pump liquid material. Dispensing will stop when the
truck is moved, and will automatically resume when the truck stops again.)
7.
Pressing pass in unload mode turns off dispensing.
8.
When unloading is complete, push blast and controller will return to the mode screen.
Using Unload Mode to Re-circulate the material in the anti-ice tanks
Verify that the anti-ice system is plumbed with a re-circulation return line; truck must be
stationary for pump to operate. If re-circulation line is not present, pump will be damaged if
operated in this mode. Note: verify proper valve settings for your system before operating in
unload mode.
a.
Turn off all boom valves on
SpreadSmart Rx
TM
.
b.
Turn on menu button, scroll down to Unload Mode and push “pass” to select;
c.
The unload mode operating screen is displayed and the rate defaults to 0%.
d.
Raise the dispensing rate to 25% using the anti-ice +/- toggle and pump will circulate
material from the tank through re-circulation return line back into the tank. Note:
leave boom valve buttones off or material will be dispensed.
e.
Turn off menu button when unloading is complete and truck will return to automatic.
Contrast
The contrast for the display is set at the factory for average brightness. Contrast can be adjusted
for personal preference and individual lighting. To adjust, push the auger and pre-wet paddles up
simultaneously, use the spinner up and down key to adjust the contrast to a readable level, and
press pass to accept. This setting will be remembered between power downs until the next time
contrast is set.
Speedometer with Re-settable Odometer (miles & feet)
SpreadSmart Rx
TM
uses the calibrated link to the truck speedometer to display a single mile
odometer in the diagnostics section of the menu screen. This odometer displays in feet and
portions of a mile, can be re-set by selecting pass = zero and re-sets automatically when it reaches
5,280 feet. This function is used for road distance measurements and its accuracy is a function of
the accuracy of the truck speedometer and the calibration.