2-20
RPMX/RPMSP-D132U & RPMSP-D180U User Manual
020-100245-03 Rev. 1 (11-2010)
Section 2: Installation and Setup
To isolate just RS-422 communications, select “RS-232 and Ethernet Joined”. In
Figure 2-23 All Joined
, only
projector #3 will respond to the RS-422 controller. To isolate just Ethernet communications, select “RS-232
and RS-422 Joined”—only projector #1 will respond via Ethernet.
2.4.8 System Integration GPIO Connector
The GPIO connector on the input panel can be used to provide a method of interfacing a wide range of external
I/O devices to the projector. Refer to
C System Integration
for complete details on pin configuration and how
to program the various pins on the connector.
2.5
Power Connection
Do not attempt operation if the AC supply and cord are not within the specified
voltage and power range.
A North American rated line cord is provided with this projector. For all other regions, make sure that
you are using a line cord, power plug and socket that meet the appropriate rating standards.
Do not use a line cord that is damaged.
2.5.1 Connecting the projector to AC
Plug an appropriately rated line cord to the AC receptacle located on the electronics module and the 3-pronged
end into a grounded AC outlet.
NOTE:
The outlet must be near the equipment and easily accessible. Use only the line cord provided with the
projector or a power cord of appropriate rating that complies with regional standards.
The input voltage to the projector must be 100-240 VAC.
CAT
5
Separate
RS232 and RS422 joined
Ethernet joined
All joined
RS232 and
1.
2.
3.
4.
RS-232
RS-232
RS-422
CA
T5
F
IGURE
2-23 A
LL
J
OINED
Summary of Contents for RPMSP-D132U
Page 1: ...RPMX RPMSP D132U RPMSP D180U U S E R M A N U A L 020 100245 03 ...
Page 2: ......
Page 3: ...RPMX RPMSP D132U RPMSP D180U U S E R M A N U A L 020 100245 03 ...
Page 12: ......
Page 34: ......
Page 110: ......
Page 114: ......
Page 133: ......