7-4
RPMX/RPMSP-D132U & RPMSP-D180U User Manual
020-100245-03 Rev. 1 (11-2010)
Section 7: Specifications
7.3
Power Requirements
NETWORK
CONTROL
Ethernet
1 RJ45 connector
REMOTE CONTROL
Type
Low Frequency IR with wired ability
Range
30 Meters
Laser Pointer
Included
Battery Type (2 Required)
AA, 1.5V Alkaline
WIRED CONTROL
Connector Type
3.5mm plug
Input Levels
High: 2.2V min.
Low: 0.9V max.
Power: 500mA @ 5V
GENERAL
RPMX-D132U
RPMSP-D132U
RPMSP-D180U
Voltage Range
100 – 240 VAC nominal
100 – 240 VAC nominal
100 – 240 VAC nominal
Line Frequency
50 – 60 Hz nominal
50 – 60 Hz nominal
50 – 60 Hz nominal
Maximum Inrush Current
30A max.
30A max.
75A max.
Current Rating (typical)
2.13A @ 100VAC
2.26A @ 100VAC
2.95A@100 VAC
0.89A @ 240VAC
0.94A @ 240VAC
1.21A@240 VAC
Power Consumption
213W
226W
276W