Step
Action
4
Shut off and depressurize the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
5
Drain the oil and condensate circuits.
On water-cooled compressors, drain the water circuits.
6
Disconnect the compressor condensate piping from the condensate drain net.
7
On water-cooled compressors, disconnect the cooling water pipes from the compressor.
8
Also read section Disposal of used material.
5.8
Use of air receiver
Instructions
Step
Action
1
This vessel can contain pressurized air; please be aware of its potential danger in case of
misuse.
2
This vessel shall only be used as compressed air/oil separator and must be operated within
the specified limits as mentioned on the dataplate.
3
No alterations shall be made to this vessel by welding, drilling or other methods of
mechanical working without written permission of the manufacturer.
4
Original bolts have to be used after opening for inside inspection. Maximum torque has to
be taken into consideration.
5
Devices for pressure and temperature control must always remain attached to this vessel.
6
This vessel has been designed and built to guarantee an operational lifetime in excess of
20 years and an infinite number of pressure load cycles. Therefore there is no intrinsic
need for in-service inspection of the vessel when used within its design limits and in its
intended application. National legislation however may require in-service inspection.
Instruction book
2920 1796 01
85