9
Technical data
9.1
Readings on display
Important
The readings are valid when operating under reference conditions. See the section
Reference conditions.
Important readings
Compressor outlet pressure
bar(e) (psig)
Depends on programmed
unloading and loading
pressures
Pressure drop over air filters
bar
Below 0.05
Pressure drop over air filters
psi
Below 0.73
Pressure difference over oil separator
bar
Below 0.8
Pressure difference over oil separator
psi
Below 12
Oil injection pressure at the compressor elements
bar(e) (psig)
Depends on programmed
unloading and loading
pressures
Compressor outlet temperature, air-cooled compressors
˚C
Approx. 29
Compressor outlet temperature, air-cooled compressors
˚F
Approx. 84
Compressor outlet temperature, water-cooled compressors
˚C
Approx. 25
Compressor outlet temperature, water-cooled compressors
˚F
Approx. 77
Compressor element outlet temperature
˚C
Between 55 and 100
Compressor element outlet temperature
˚F
Between 131 and 212
Cooling air inlet temperature
˚C
Below 40
Cooling air inlet temperature
˚F
Below 104
Cooling water temperature
˚C
Below 50
Cooling water temperature
˚F
Below 122
9.2
Reference conditions
Reference conditions
Absolute inlet pressure
bar(a)
1
Absolute inlet pressure
psi
14.5
Relative air humidity
%
0
Air inlet temperature
˚C
20
Air inlet temperature
˚F
68
Instruction book
2920 1796 01
103