Control panel
Reference
Name
1
Press stop button (13). LED (7) goes out. The compressor runs unloaded for 30 seconds
and then stops.
2
To stop the compressor in the event of an emergency, press the emergency stop button.
Alarm LED (4) blinks. After remedying the fault, unlock the button by pulling it out
3
Close the air outlet valve.
4
Open the condensate drain valves.
For compressors equipped with electronic water drains, press the test buttons on top of
the electronic drains until the air system between the air receiver and the outlet valve is
fully depressurized.
5
Switch off the voltage.
6
On water-cooled compressors, close the water shut-off valves.
7
On water-cooled compressors, if the compressor is installed in a room where freezing
temperatures are expected, drain the cooling system by opening the drain valves in the
water inlet and outlet pipes (customer's installation).
5.7
Taking out of operation
Disconnecting the compressor
At the end of the service life of the compressor, proceed as follows:
Step
Action
1
Stop the compressor and close the air outlet valve.
2
Switch off the voltage and disconnect the compressor from the mains.
3
Depressurize the compressor by opening the drain valve and loosening the oil filler plug
one turn.
For compressors equipped with electronic water drains, press the test buttons on top of
the electronic drains until the air system between the air receiver and the outlet valve is
fully depressurized.
Instruction book
84
2920 1796 01