8
Problem solving
8.1
Problem solving
Warning
Before carrying out any maintenance, repair work or adjustment, stop the compressor,
press the emergency stop button and switch off the voltage. Close the air outlet valve and
open the manual condensate drain valves.
Open and lock the isolating switch.
The operator must apply all relevant
.
Control panel
Faults and remedies
If the alarm LED is lit or flashes, consult sections Event history menu or Service menu.
Unit is shut down
The alarm LED will flash indicating either that the outlet temperature is too high or that the motor overload
relay has tripped. Remedy the problem. It may be necessary to reset the display after remedying the fault:
press the “Reset” key (2); the message “All protection functions are OK” will appear, after which the
compressor can be restarted.
Excessive oil consumption
Have the compressor inspected by a service representative.
Instruction book
2920 1796 01