Nominal working pressure
See section Compressor
data
Cooling water inlet temperature
˚C
20
Cooling water inlet temperature
˚F
68
9.3
Limits
Limits
Maximum air inlet/ambient temperature
˚C
40
Maximum air inlet/ambient temperature
˚F
104
Minimum air inlet/ambient temperature
˚C
0
Minimum air inlet/ambient temperature
˚F
32
Maximum cooling air temperature
˚C
40
Maximum cooling air temperature
˚F
104
Minimum cooling air temperature
˚C
0
Minimum cooling air temperature
˚F
32
Maximum working pressure
See section Compressor
data
Maximum cooling water inlet temperature
˚C
40
Maximum cooling water inlet temperature
˚F
104
Maximum cooling water outlet temperature (open systems)
˚C
50
Maximum cooling water outlet temperature (open systems)
˚F
122
Maximum cooling water outlet temperature (recirculating
systems)
˚C
60
Maximum cooling water outlet temperature (recirculating
systems)
˚F
140
Maximum cooling water inlet pressure
bar(e)
10
Maximum cooling water inlet pressure
psig
145
9.4
Settings of safety valve
Compressor type
Setting
For compressors with a maximum working pressure of 7.5 or 8.5 bar
11 bar (e)
For compressors with a maximum working pressure of 109 or 123 psi
160 psig
For compressors with a maximum working pressure of 6.9, 8.6, 10, 10.4, 13 or 13.8
bar
15 bar (e)
For compressors with a maximum working pressure of 100, 125, 145, 150, 188 or
200 psi
217 psig
Instruction book
104
2920 1796 01
Summary of Contents for CPF 270
Page 1: ...CPF 270 CPF 340 Instruction book ...
Page 2: ......
Page 61: ...Instruction book 2920 1796 01 59 ...
Page 93: ...Vent filler and drain plugs on air cooled compressors Instruction book 2920 1796 01 91 ...
Page 120: ......
Page 121: ......
Page 122: ...No 2920 1796 01 2013 02 ...