Reference
Description
(1)
Cover serial number here
(2)
Data plate here
Corrosion allowance
1 mm (0.039 in)
Minimum wall thickness vessel
8 mm (0.315 in)
Minimum wall thickness cover
12 mm (0.472 in)
Lifetime
infinite according to EN13445 §3&6
Delta p
13.3 bar (192.9 psi)
Casting factor cover
0.8