Example of a cubicle without starter
Step
Action
1
Check that the electrical connections correspond to the local codes. The installation must
be earthed and protected by fuses in all phases. An isolating switch must be fitted.
2
Check the wires on transformers (T1/T2) for correct connection.
3
Check the setting of the circuit breakers (see the section Settings of circuit breakers).
Water circuit
Step
Action
1
Check that the cooling water drain valves (customer’s installation) in the inlet and outlet
lines are closed.
2
Check that the water shut-off valves (customer’s installation) are open.
3
Open the water regulating valve and check for water flow.
Instruction book
78
2920 1796 01