Page 1: ...instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...guages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or placi...

Page 3: ...nd on a stable and even ground It must not stand sloped during transport or use Make sure that all open connections are closed with protective caps during transport to avoid pol lutants and water from entering To ensure a good performance the compressor should stand in an aired clean and cool area Dusty or dirty air as well as high temperatures in the surrounding need to be avoided Make sure that ...

Page 4: ...ure switch Make sure the pressure switch works under the rated work ing pressure When using the oil water separator After switching the compressor off please use your finger to press the needle below the oil water separator to discharge the dirty water within the separ ator The air pressure can be adjusted by the button on the oil water separator Turn the knob clockwise to increase the air pressur...

Page 5: ...ase the air easily Pull the shaft down to reset it The air filter should be cleaned or replaced every 500 hours Simultaneously take out the air valve and clean it as well When the air delivery volume is much less than the rated one please check if the air filter is blocked Also check whether all connections are still tight Check for leakages as well If the piston rubber bowl is worn because of dus...

Page 6: ...re Check the voltage must not be 10 lower than rated voltage Move the compressor to a ventilated area Air pressure is redu ced when the machi ne is turned off Air pipe loose or leaking Water drain valve open Check valve leakage Check and fix it Tighten the drain valve Remove and clean it replace when necessary Too much water in delivered air Plenty of water in the tank Humidity is too high Drain t...

Page 7: ...Exploded View Drawing and Parts List by WilTec Wildanger Technik GmbH Artikel 61017 Seite 7 http www WilTec de http www aoyue eu 10 2020 1 http www teichtip de ...

Page 8: ...for observation hole 2 15 Connection pipe sealing circle 2 43 Drainage valve 1 16 Pan head screws with cross recess M4 x 6 2 44 Air tank 1 17 Limiting stopper 2 45 Washer holding screws 2 18 Air outlet valve clack 2 46 Big foot washer 2 19 Valve plate 2 47 Foot washer holding screw cap 2 20 Air intake valve clack 2 48 Power cable 1 21 Metal gasket 2 49 Check valve 1 22 Crankshaft 2 50 Magnetic val...

Page 9: ...ts out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this art icle you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Materials recycling helps reduce the consump...

Page 10: ...ectives Cet appareil est conform aux dierectives européennes 2006 42 EC 2014 35 EU 2014 30 EU Es ist nach folgenden harmonisierten Normen geprüft worden It has been tested with the following harmonised standards Il a été testé à partir des norms harmonisées suivantes EN ISO 12100 2010 EN 1012 1 2010 EN 60204 1 2006 A1 2009 AC 2010 EN 61000 6 1 2007 EN 61000 6 3 2007 A1 2011 AC 2012 EN 61000 3 2 20...