EMISSION CONTROLS AND FUEL SYSTEM 185
Holley 4150 and 4160 Specifications
Year
Identifi-
cation
No.®
Engine
Horse-
power
Accelerator Float
Pump Level Lever
Choke (Dry) Adjustment
Setting (in.) (In.)
(in.)
Choke
Unloader
Clearance
(in.)
Fast Idle
On Car
(ipm)
Choke
Vacuum
Break
(in.)
R3367A
300, 350
® .015 ®
.260
2,200
.170
R 3 4 1 6 A ®
300, 350
® .015 ®
.260
2,200
.170
R3370A
390
© .015 ©
.260
2,000
.180
R 3 4 3 3 A ©
390
® .015 ©
.260
2,000
.180
1966
R3247A
425
© .015 ©
.350
2,000
.350
R3810A
300, 350
® .015 ©
.265
2,000
.190
R 3 8 1 4 A ©
300, 350
© .015 ©
.265
2,000
.175
R3811A
390
© .015 ©
.265
2,200
.175
R 3 8 1 5 A ©
390
© .015 ©
.265
2,200
.175
1967
R3418A
430
© .015 ©
.350
2,200
.350
1968
R4054A
430
© .015 ®
.350
2,200
.300
1969
R4296A
430
© .015 ®
.350
2,200
.350
R4346
370
© .015 ©
.350
2,200
.300
1970
R4296A
430
© .015 ®
.350
2,200
.350
R 4 8 0 1 A ®
330
® .015 ©
.350
2,200
.350
R 4 8 0 0 A ®
330
® .015 ©
.350
2,200
.350
R 4 8 0 3 A ®
425
® .015 ®
.350
2,200
.350
1971
R 4 8 0 2 A ®
425
® .015 ©
.350
2,200
.350
R 6 2 3 9 A ®
255
® .015 ©
.350
2,350
.350
1972
R 6 2 3 8 A ®
255
® .015 ©
.350
2,350
.350
® Located on the tag attached to the carburetor, or on the casting or choke plate
© A.I.R.—Air Injector Reactor System
©Prim.—.170", Sec.—.300"
® Hold the choke valve closed and push downward on the coil rod to the end of travel. The top of the rod should be
even with the top of the hole in the choke lever. Bend the rod to adjust. ® Hold the choke valve closed. Pull upward
on the coil rod to the end of travel. The bottom of the rod end which slides
into the hole in the choke lever should be in line with the notch. Bend the rod to adjust. ® Prim.—.350", Sec.—.450"
©Prim.—.350", Sec.—.500" ® Man. Trans. ® Auto. Trans. ® Float centered in bowl ©Hold the choke valve open.
Pull downward on the coil rod to the end of travel. The bottom of the rod end which
slides into the hole in the choke lever should be in line with the notch. Bend the rod to adjust.
Carter WCFB & AFB
Main Metering Metering Rod Tlirottle Bom
Jet (In.) (in.) (In.)
Year
Application
Identification
No.
Float
Level
(In.)
Float Pump
Drop Rod
(in.) (in.)
Choke
Setting
Prim Sec Prim Sec Prim
Sec
Fast
Idle
(ipm)
1 9 6 3- 6 5
250 hp
3501 S (M.T.)
3500S (A.T.)
%2©
3
/4
1
/2
index
0.086 0.0635 0.042 0.067 1
7
/i
S
1
7
/16
1750
300,340 hp 3461S(M.T.) %a %
1
/
2
1 lean 0.104 0.0689 0.060 0.069 1
9
/ie 1
11
/ie 1750
3460S (AT.)
© %" for secondary