Intelect® Advanced Therapy System
SPECIFICATIONS
21
Microcurrent is a monophasic waveform of very low intensity.
The literature reports beneficial effects of this waveform in the
treatment of wounds. The physiological working mechanism of
this effect is as yet not clearly understood. It is thought to
stimulate tissue healing by stimulating the 'current of injury', a
current which naturally occurs in healing tissue.
Output Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrodes or Probe
Output Intensity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0-1000.0 µA
Polarity . . . . . . . . . . . . . . . . . . . . . . . . . .Positive, Negative or Alternating
Treatment Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-60 Min
Available on channels . . . . . . . . . . . . . . . . . . . . . . . . 1 & 2, 3 & 4 Option
VMS Burst is a symmetrical biphasic waveform delivered in a burst
format. Because the pulse is relatively short, the waveform has a
low skin load, making it suitable for applications requiring high
intensities, such as in muscle strengthening protocols.
Output Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Electrodes
Output Intensity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-255 mA
Channel Mode . . . . . . . . . . . . . . . . . . . . . . . . . Single, Reciprocal, Co-Contract
Phase Duration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-1000 µsec
Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CC or CV*
Anti-Fatigue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Off or On
Set Intensity . . . . . . . . . . . . . . . . . . . . . .Individual Channel Intensity Setting in
Reciprocal and Co-Contract modes
Cycle Time . . . . . . . . . . .Continuous, 5/5, 4/12, 10/10, 10/20, 10/30, 10/50
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-200 pps
Ramp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.5 sec, 1 sec, 2 sec, 5 sec
Treatment Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-60 min
Available on Channels . . . . . . . . . . . . . . . . . . . . . . . . 1 & 2, 3 & 4 Option
*CC= Constant Current
CV= Constant Voltage
WAVEFORM SPECIFICATIONS (continued)
Microcurrent
VMS
TM
Burst
Supplied by EME Services Ltd