5.0 Installation & Setup
20
The power source is connected to the cutter at in the junction box located at the rear, right hand side
of the machine. The power is then run up to the main transformer mounted to the side of the machine,
under the top hood.
5.8.1 Three Phase Hook-Up
1. Disconnect the power at the main power panel and lock it out to prevent accidental power-up.
See Power Lock-Out procedure, page 5.
2. Thread the power cord through the knock-out hole in the junction box located near the floor in
the lower left hand corner of the machine rear. Secure it with a conduit connector.
3. Fasten the ground lead to the ground terminal lug found in the junction box.
4. Use wire nuts to join the three power leads to the L1, L2 and L3 leads found in the junction
box.
5. Close all doors and guards, unlock the main power and switch it on. The machine should
now have power.
6. Press both cut buttons simultaneously to activate the motor and check to make sure it is
turning the same direction as the arrow on the motor casing. If it isn’t, disconnect the power
and simply exchange any two leads of the power cord as in Figure 14 on page 20. The motor
will now turn the correct direction. Double check to make sure.
Figure 15
5.9 Line Light
The Titan 265 is equipped with two lights, which provide a line of light on the paper in the
approximate location of where the paper will be cut. The lights come on when power to the machine
is turned on. The light from each bulb reaches the table after passing between the knife and clamp.
Each light is focused with a socket head cap screw (Figure 16).