Revision 1.3a
Page 54
XLR 550 Manual
[Example 8-5] show specific port information
XLR550> (enable)
show port
e0
Description: 10/100BASE-TX_0
Link Mode: auto
Flow Control: disable
Port VLAN Members: s0,e1,e2,e3
PVID: 1
Double Tagging: disable
Max Rate: unlimit
Fixed Priority: 0
Classifier: fixed
Link State: dn
Duplex: -
Speed: -
XLR550> (enable)
4.8.3
set auto-ratecontrol
When auto-ratecontrol is enabled, the maximum rate of 2BASE-TL port is set to same value with
the total link rate, automatically. That is, the port configuration parameter,
“
maxrate
”
, is ignored
internally. When disabled, the
“
maxrate
”
parameter is applied to the system.
Usage
set auto-ratecontrol
{
enable
|
disable
}
Arguments
keyword
Description
enable
When auto-ratecontrol is enabled, the maximum rate of 2BASE-
TL port is set to same value with the total link rate,
automatically. That is, the port configuration parameter,
“
maxrate
”
, is ignored internally.
disable
When disabled, the
“
maxrate
”
parameter is applied to the system.
Confirmation
see also,
“
show auto-ratecontrol
”
,
“
set port
”
.
Examples
[Example 8-6] enable auto-ratecontrol
XLR550> (enable)
set auto-ratecontrol enable
XLR550> (enable)