87
ENG
μc0300053EN rel. 2.2 - 14.12.2021
Parameter table
User
Display
C
ode
Description
Def.
Min
Max
U
O
M
R/W
Modbus
S
S012
Source fan 1 circuit 2: maintenance hour threshold
(X100)
99
0
999
h
R/W
HR217
S
S013
Source fan 1 circuit 2: reset hour counter
0
0
1
-
R/W
CS034
S
x
S014
Source ON/OFF fan circuit 2: operating mode 0=AUTO -
1=OFF - 2=ON
0
0
2
-
R/W
HR218
S
x
S015
Source modulating fan circuit 2: operating mode
0=AUTO - 1=0% - 2=1%, ..101=100%
0
0
101
-
R/W
HR219
S
S016
Source fan: cold climate temperature threshold
-0.5
-999.9
999.9
°C/°F
R/W
HR220 (2R)
S
S017
Source fan: min cold climate speed
10.0
0.0
100.0
%
R/W
HR222 (2R)
S
S018
Source fan: cold climate speed at start-up
50.0
0.0
100.0
%
R/W
HR224 (2R)
S
S019
Source fan: cold climate speed at start-up time
5
0
300
s
R/W
HR226
S
x
S020
Enable noise reduction - 0/1=No/Yes
0
0
1
-
R/W
CS035
S
S021
Noise reduction time band: start hours
22
0
23
h
R/W
HR167
S
S022
Noise reduction time band: start minutes
30
0
59
min
R/W
HR212
S
S023
Noise reduction time band: end hours
8
0
23
h
R/W
HR041
S
S024
Noise reduction time band: end minutes
30
0
59
min
R/W
HR042
S
S025
Source fan: noise reduction set point
45.0
0.0
999.9
°C/°F
R/W
HR231 (2R)
S
S026
Compressor start delay after pump start
30
0
999
s
R/W
HR233
S
S027
Pump shutdown delay after compressor off 10
0
999
s
R/W
HR234
S
S028
Source fan in cooling: set point
30.0
-999.9
999.9
°C/°F
R/W
HR235 (2R)
S
S029
Source fan in heating: set point
10.0
0.0
99.9
°C/°F
R/W
HR237 (2R)
S
S031
Source fan in cooling: set point at start-up
45.0
0.0
999.9
°C/°F
R/W
HR241 (2R)
S
S032
Source fan: delay at start-up in cooling
240
0
999
s
R/W
HR243
S
S034
Source fan: diff erential in cooling
15.0
0.0
99.9
K
R/W
HR246 (2R)
S
S035
Source fan: diff erential in heating
5.0
0.0
99.9
K
R/W
HR248 (2R)
S
S036
Modulating source fan: min speed value
20.0
0.0
100.0
%
R/W
HR250 (2R)
S
S037
Modulating source fan: max speed value
80.0
0.0
100.0
%
R/W
HR252 (2R)
S
S039
Defrost: start temperature
-1.0
-99.9
99.0
°C/°F
R/W
HR254 (2R)
S
S040
Defrost: reset start defrost delay threshold
1.0
S039
99.9
°C/°F
R/W
HR256 (2R)
S
S041
Defrost: delay at start-up
30
0
999
min
R/W
HR258
S
S042
Defrost: end temperature
52.0
-999.9
999.9
°C/°F
R/W
HR259 (2R)
S
S043
Enable sliding defrost - 0/1=No/Yes
0
0
1
-
R/W
CS037
S
S044
Operation time at min capacity before cycle reversing
20
0
999
s
R/W
HR261
S
S045
Operation time at min capacity after cycle reversing
30
0
999
s
R/W
HR262
S
S046
Defrost: min duration
1
0
99
min
R/W
HR263
S
S047
Defrost: max duration
5
0
99
min
R/W
HR264
S
S048
Dripping: duration - 0=Dripping not performed
90
0
999
s
R/W
HR265
S
S049
Post-dripping: duration - 0=Post-dripping not perfor-
med
30
0
999
s
R/W
HR266
S
S050
Minimum delay between consecutive defrosts
20
0
999
min
R/W
HR267
S
S051
BDLC compressor speed in defrost
80.0
0.0
999.9
rps
R/W
HR382 (2R)
S
S052
BLDC compressor speed for cycle reversing in defrost
40.0
0.0
999.9
rps
R/W
HR384 (2R)
S
S053
Defrost synchronisation - 0=Independent - 1=Separate
- 2=Simultaneous
0
0
2
-
R/W
HR272
M
S054
4-way valve: pressure diff erential for reversing
3.0
0.0
999.9
bar/psi
R/W
HR274 (2R)
M
S055
Compressor after defrost - 0/1=On/Off
0
0
1
-
R/W
CS038
S
S056
BLDC smart start: duration (*)
20
0
999
s
R/W
HR278
S
S057
Source frost protection: alarm threshold
-0.8
-999.9
999.9
K/R
R/W
HR279 (2R)
S
S058
Source frost protection: alarm diff erential
30.0
0.0
999.9
K/R
R/W
HR281 (2R)
S
S059
Frost protection alarm delay at threshold -1K
30
0
999
s
R/W
HR283
S
S060
Source: outside air temperature probe off set
0.0
-99.9
99.9
K/R
R/W
HR284 (2R)
M
S061
Source fan: output logic - 0/1=NO/NC
0
0
1
-
R/W
CS039
M
S062
Source pump: output logic - 0/1=NO/NC
0
0
1
-
R/W
CS040
S
S063
Reversing valve: output logic - 0/1=NO/NC
0
0
1
-
R/W
CS041
S
S064
Type of source air circuit
0=Independent - 1=Common
0
0
1
-
R/W
CS042
S
S065
Type of source fan - 0/1=Modulating/ON-OFF
0
0
1
-
R/W
CS044
S
S068
Unit type - 0=Air - 1=Water
0
0
1
-
R/W
CS046
S
S069
Defrost with fans: outside temperature threshold
0.0°C/32.0°F=Function disabled
0.0
0.0
99.9
-
R/W
HR736
S
S072
Source pump activation
0=on with unit on
1=on with compressor on
2=modulating on/off with condensing temperature
0
0
2
-
R/W
HR213
S
S073
Compressor status at start defrost
0=On minimum speed - 1=Off
0
0
1
-
R/W
CS92
Tab. 6.d