Alarms and signals
C
ode Description
Reset Eff ect
Priority
Delay
N
o. of
attempts
Evaluation
period (s)
A34
EVD circuit 1: LowSH
A
-
Fault, circuit 1
Param. S008
-
-
A35
EVD circuito 1: LowSH
M
Circuit 1 shutdown
Fault, circuit 1
Param. E024
-
-
A36
EVD circuit 1: LOP
A
-
Fault, circuit 1
Param. E025
-
-
A37
EVD circuit 1: MOP
A
Circuit 1 shutdown
Fault, circuit 1
Param. E026
-
-
A38
EVD circuit 1: motor error
M
Circuit 1 shutdown
Fault, circuit 1
No
-
-
A39
EVD circuit 1: emergency closing
A
-
Fault, circuit 1
No
-
-
A40
EVD circuit 1: incomplete valve closing
A
-
Fault, circuit 1
No
-
-
A41
EVD circuit 1: offl
ine
A
Circuit 1 & 2 shut-
down
Serious, circuit
1 & 2
30s
-
-
A42
Circuit 1: envelope alarm + zone alarm
A (R)
Circuit 1 shutdown
Serious, circuit 1 Param. P003
3
3600
A43
BLDC circuit 1: high pressure diff erential atstart-up
A
BLDC 1 not
enabled to start
Serious, circuit 1 5min
-
-
A44
BLDC circuit 1: failed start-up
A (R)
-
Serious, circuit 1 45s
5
3600
A45
BLDC circuit 1: low pressure diff erential
A
Circuit 1 shutdown
Serious, circuit 1 Param. P004
-
-
A46
BLDC circuit 1: high gas discharge temp.
M
Circuit 1 shutdown
Serious, circuit 1 No
-
-
A47
Speed drive 1: offl
ine
A
Circuit 1 shutdown
/ BLDC 1
Serious, circuit 1 30s
-
-
A48
Speed drive 1: alarm + error code
A (R)
Circuit 1 shutdown
/ BLDC 1
Serious, circuit 1 No
3
3600
A49
Unit: circuit 2 offl
ine
A
-
Serious, circuit 2 30s
-
-
A50
Circuit 2 unit: no. permanent memory writes
M
-
Fault
No
-
-
A51
Circuit 2 unit: permanent memory writes
M
-
Fault
No
-
-
A52
Circuit 2: condensation pressure probe
A
Circuit 2 shutdown
Serious, circuit 2 10s
-
-
A53
Circuit 2: condensing temperature probe
A
Circuit 2 shutdown
Serious, circuit 2 10s
-
-
A54
Circuit 2: evaporation pressure probe
A
Circuit 2 shutdown
Serious, circuit 2 10s
-
-
A55
Circuit 2: evaporation temperature probe
A
Circuit 2 shutdown
Serious, circuit 2 10s
-
-
A56
Circuit 2: discharge temperature probe
A
Circuit 2 shutdown
Serious, circuit 2 10s
-
-
A57
Circuit 2: suction temperature probe
A
Circuit 2 shutdown
Serious, circuit 2 10s
-
-
A58
Circuit 2: high pressure switch
Param.
U081
Circuit 2 shutdown
Serious, circuit 2 No
-
-
A59
Circuit 2: high condensing pressure/temperature
transducer
M
Circuit 2 shutdown
Serious, circuit 2 No
-
-
A60
Circuit 2: low pressure transducer
A (R)
Circuit 2 shutdown
Serious, circuit 2 No
3
3600
A61
Circuit 2: frost protection evaporation temperature
Param.
U081
Circuit 2 shutdown
Serious, circuit 2 Param. U052
-
-
A62
Circuit 2: low pressure switch
Param.
U081
Circuit 2 shutdown
Serious, circuit 2 Param.
C049, C050
3
3600
A63
Circuit 2: compressor 1 overload
M
Comp. 1 circ.
2 shutdown
Fault, circuit 2
No
-
-
A64
Circuit 2: compressor 2 overload
M
Comp. 2 circ.
2 shutdown
Fault, circuit 2
No
-
-
A65
Circuit 2: compressor 1 maintenance
A
-
Fault
Param. C006
-
-
A66
Circuit 2: compressor 2 maintenance
A
-
Fault
Param. C003
-
-
A67
Circuit 2: source fan maintenance
A
-
Fault
Param. S012
-
-
A68
EVD circuit 2: LowSH
M
Circuit 2 shutdown
Serious, circuit 2 Param. E024
-
-
A69
EVD circuit 2: LOP
A
Circuit 2 shutdown
Serious, circuit 2 Param. E025
-
-
A70
EVD circuit 2: MOP
A
Circuit 2 shutdown
Serious, circuit 2 Param. E026
-
-
A71
EVD circuit 2: motor error
M
Circuit 2 shutdown
Serious, circuit 2 No
-
-
A72
EVD circuit 2: emergency closing
A
Circuit 2 shutdown
Serious, circuit 2 No
-
-
A73
EVD circuit 2: incomplete valve closing
A
Circuit 2 shutdown
Serious, circuit 2 No
-
-
A74
EVD circuit 2: offl
ine
A
Circuit 2 shutdown
Serious, circuit 2 30s
-
-
A75
Circuit 2: envelope alarm + zone alarm
A (R)
Circuit 2 shutdown
Serious, circuit 2 Param. P003
3
3600
A76
BLDC circuit 2: high pressure diff erential at start-up A
BLDC 2 not
enabled to start
Serious, circuit 2 5min
-
-
A77
BLDC circuit 2: failed start-up
A (R)
-
Serious, circuit 2 45
5
3600
A78
BLDC circuit 2: low pressure diff erential
A
Circuit 2 shutdown
Serious, circuit 2 P004
-
-
A79
BLDC circuit 2: high gas discharge temp.
M
Circuit 2 shutdown
Serious, circuit 2 No
-
-
A80
Speeddrive circuit 2: offl
ine
A
Comp. 1 circ.
2 shutdown
Serious, circuit 2 30s
-
-
A81
Speed drive circuit 2: alarm +code error
A (R)
Comp. 1 circ.
2 shutdown
Serious, circuit 2 No
3
3600
A85
Source delivery water temperature probe broken
or disconnected - circuit 1
A
Circuit 1 shutdown
Serious, circuit 1 No
-
-
A87
Unit: EVD Evolution not compatible
A
Unit shutdown
Serious, unit
No
-
-
Tab. 8.b