CDE500 Vector Control AC Drive
Chapter 6 Parameters Description
Example 2: E5.38 = 0(Base on output frequency).
Figure 6- 41 Sleep base on output frequency
E5.42
Range: 0.0~100.0
Default: 100.0
Unit: %
PID setting high limit
PID setting value higher limit of internal operation.
E5.43
Range: 0.0~100.0
Default: 0.0
Unit: %
PID setting low limit
PID setting value lower limit of internal operation.
E5.44
①
Base value
selection of PID
sleep and wake
up threshold
Range: 0~1
Default: 0
The Unit/Range of
E5.36
and
E5.39
is determined by
E5.44
.
0:Unit is Percentage (%),base value is PID setting and range is
0.0~200.0%.
1:Unit is the same as PID engineering unit(
E5.00
),range is
E5.03
~
E5.02
.