CDE500 Vector Control AC Drive
Chapter 6 Parameters Description
d6.11
Range: 0 ~ 7
Default: 0
Motor 2 Upper
torque limit
Source of
reverse motoring
0: d2.10
1: AI1
2: AI2
3: AI3
4: X6/FI
5: Communication
6: MIN
(
AI1,AI2
)
7: MAX
(
AI1,AI2
)
This parameter allows user to select the desired source as upper torque to
limit the motor output torque when the motor is running reverse in
motoring mode. More information, see d6.12.
d6.12
Range: 0.0 ~ 200.0%
Default: 150.0%
Motor 2 Preset
upper torque
limit of reverse
motoring
Unit: %
When d6.11 is set to 0, this parameter is used as upper torque limit when
the motor is running reverse in motoring mode. If the torque upper limit is
analog, pulse or communication setting, 100% of the setting corresponds
to the value of d6.12, and 100% of the value of d6.12 corresponds to the
motor rated torque.
d6.13
Range: 0 ~ 7
Default: 0
Motor 2 Upper
torque limit
source of
forward
generating
0: d2.10
1: AI1
2: AI2
3: AI3
4: X6/FI
5: Communication
6: MIN
(
AI1,AI2
)
7: MAX
(
AI1,AI2
)
This parameter allows user to select the desired source as upper torque to
limit the motor output torque when the motor is running forward in
generating mode. More information, see d6.14.
d6.14
Range: 0.0 ~ 200.0
Default: 150.0
Motor 2 Preset
upper torque
limit of forward
generating
Unit: %
When d6.13 is set to 0, this parameter is used as upper torque limit when
the motor is running forward in generating mode. If the torque upper limit is
analog, pulse or communication setting, 100% of the setting corresponds
to the value of d6.14, and 100% of the value of d6.14 corresponds to the
motor rated torque.
d6.15
Range: 0 ~ 7
Default: 0
Motor 2 Upper
torque limit
source of reverse
generating
0: d2.10
1: AI1
2: AI2
3: AI3
4: X6/FI
5: Communication
6: MIN
(
AI1,AI2
)
7: MAX
(
AI1,AI2
)
This parameter allows user to select the desired source as upper torque to
limit the motor output torque when the motor is reverse forward in
generating mode. More information, see d6.16.
d6.16
Range: 0.0 ~ 200.0
Default: 150.0
Motor 2 Preset
upper torque
limit of reverse
generating
Unit: %
When d6.15 is set to 0, this parameter is used as upper torque limit when
the motor is running reverse in generating mode. If the torque upper limit
is analog, pulse or communication setting, 100% of the setting
corresponds to the value of d6.16, and 100% of the value of d6.16
corresponds to the motor rated torque.