CHAPTER 9 INSTALLATION
COPYRIGHT © 1999 CANON INC. CANON PC800s/900s REV.0 AUG. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
9-1
I.
SELECTING A SITE
Keep the following in mind when selecting a site for installation; if possible, visit the user’s
before delivery of the machine:
• The site offers a power outlet whose rating is as specified (±10%) and which may be used
exclusively for the machine.
• The site is between 7.5°C/45.5°F and 32.5°C/90.5°F in temperature and between 5% and
85% in humidity. Avoid an area near water faucets, water boilers, humidifiers, and refrigera-
tors.
• Avoid areas near sources of fire. The site must not be subject to ammonium gas or direct rays
of the sun. (As necessary, provide curtains.)
• The site must be well ventilated.
The level of ozone generated by the machine should not affect the health of people around it.
Some, however, may find the odor to be rather unpleasant, and ventilation is a very important
factor.
• The floor of the site must ensure that the machine’s feet will remain in contact, and will hold
the machine level.
• The machine must be at least 10 cm/3.9 in. away from any wall, and there must be adequate
space for work involving the machine.
Figure 9-101
10cm min.
10cm min.
Summary of Contents for PC920