11-3
COPYRIGHT © 1999 CANON INC. CANON PC800s/900s REV.0 AUG. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
I.
MAINTENANCE AND INSPECTION
A.
Image Adjustment Basic Procedure
Making Pre-Checks
Adjusting the Optimum Density
Clean the parts.
Is the copy density
correction switch (SW101) set
to the middle index?
(Note 1)
Set it at
the middle.
Select non-AE, and set the copy density
adjusting lever to the middle index; then,
make two to three copies of the Test
Sheet (NA-3).
Check the following:
1. Density of gray scale No. 9
2. Presence/absence of difference between front
and rear (Note 2)
3. Density of gray scale No. 1 (good or bad; Note 2)
4. Fogging of background (Note 2)
NO
YES
Scanning system,
pickup/feeding system,
delivery assembly
Check the following:
1. Cartridge
2. Scanning lamp
3. AE sensor PCB
4. DC controller PCB
5. Composite power supply PCB
(See the appropriate troubleshooting
procedure.)
Is the optimum
density obtained by intensity
adjustment?
(Note 3)
Can the
deviation be corrected
using the copy density correction
switch (SW101)?
(Note 1)
Is gray scale No. 9
barely visible?
END
YES
YES
YES
NO
NO
NO
Note:
1. Applies only if the machine is equipped with a copy
density correction switch (SW101).
2. The machine is not equipped with a function to
correct image faults. See the appropriate
troubleshooting procedure.
3. See p. 11-42.
Summary of Contents for PC920
Page 12: ......
Page 34: ......
Page 36: ......
Page 48: ......
Page 50: ......
Page 92: ......
Page 94: ......
Page 122: ......
Page 124: ......
Page 162: ......
Page 164: ......
Page 180: ......
Page 206: ......
Page 240: ......
Page 242: ......
Page 256: ......
Page 263: ......
Page 265: ......
Page 355: ......
Page 383: ......