8
8
8-75
8-75
Service Mode > COPIER > FUNCTION > CLEAR
Service Mode > COPIER > FUNCTION > CLEAR
COPIER> FUNCTION> CLEAR
ALL
Clearing setting information
Details
• User mode setting values
• Service mode setting values (excluding the service counter)
• ID and password of the system administrator
• Communication management/print/jam/error log
• E719 error (counter meter-installed models only)
• The following items are not cleared/initialized.
• Service counter
• Factory adjustment values of the Reader/ADF
Use case
At installation
Adj/set/operate method 1) Select the item, and then press Start key.
2) Turn OFF/ON the main power switch.
Related service mode COPIER> OPTION> BODY> SIZE-LC
ERDS-DAT
Initialization of E-RDS SRAM data
Details
To initialize the SCM value of the Embedded-RDS stored in the SRAM.
SCM values are ON/OFF of E-RDS, server’s port number, server’s
SOAP URL, and communication schedule with the server (how often the
data is acquired), etc.
The value set by COPIER> FUNCTION> INSTALL> E-RDS, RGW-
PORT, RGW-ADR, COM-LOG is cleared.
Use case
When upgrading the Bootable in the E-RDS environment
Adj/set/operate method Select the item, and then press Start key.
Caution
The method of using the SRAM in E-RDS differs depending on the
Bootable version. Therefore, unless the SRAM data is cleared at the
time of version upgrade, data inconsistency occurs.
Display/adj/set range
At normal termination: OK, At abnormal termination: NG
Related service mode COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, RGW-ADR,
COM-LOG
ERR
Clear of error code
Details
To clear error codes (E000, E001, E002, E003, E717).
Use case
At error occurrence
Adj/set/operate method 1) Select the item, and then press Start key.
2) Turn OFF/ON the main power switch.
DC-CON
RAM clear of DC Controller PCB
Details
To clear the RAM data of the DC Controller PCB.
Use case
When clearing the RAM data of the DC Controller PCB
Adj/set/operate method 1) Select the item, and then press Start key.
2) Turn OFF/ON the main power switch.
Caution
• Output the service mode setting values by P-PRINT before execution.
After execution, enter necessary setting values.
• The RAM data is cleared After the main power switch is turned OFF/
ON.
Related service mode COPIER> FUNCTION> MISC-P> P-PRINT
CNT-DCON
Clear of DC Controller service counter
Details
To clear the service counter counted by the DC Controller PCB.
Use case
When clearing the service counter counted by the DC Controller PCB
Adj/set/operate method Select the item, and then press Start key.
COPIER> FUNCTION> CLEAR
OPTION
Not used
REG-CLR
Clear of image position correction value
Details
To clear the value when the correction value that is adjusted by image
position correction control becomes a faulty value due to some reasons.
When color displacement cannot be corrected by image position
correction control, clear the correction value and turn OFF/ON the
machine or execute “Quick Adjust” and “Auto Correct Color Mismatch”
in Settings/Registration so that image position correction is executed
again.
Use case
• When color displacement cannot be corrected by image position
correction control
• When a failure occurs in correction in an oblique direction
Adj/set/operate method Select the item, and then press Start key.
Related UI menu
Adjustment/Maintenance> Auto Adjust Gradation> Quick Adjust
Adjustment/Maintenance> Auto Correct Color Mismatch
T-8-29
Summary of Contents for imageRUNNER C1325 Series
Page 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Page 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...