![Canon imageRUNNER C1325 Series Service Manual Download Page 380](http://html.mh-extra.com/html/canon/imagerunner-c1325-series/imagerunner-c1325-series_service-manual_57874380.webp)
7
7
7-9
7-9
Error•Jam•Alarm > Error Code > Error Code Details
Error•Jam•Alarm > Error Code > Error Code Details
Error
code
Detail
Code
Item
Description
E010 0002 Title
Bk Drum_ITB Motor error
Description The specified speed could not be detected for 500 consecutive msec
although it became the specified speed at least once from the startup of
the Bk Drum_ITB Motor in the Main Drive Unit.
Remedy
[Related parts]
• Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY)
• Harnesses connecting the Bk Drum_ITB Motor (M02/J5702), the
Relay Connector (8P) and the DC Controller PCB (UN04/J140) (Unit of
replacement: MAIN DRIVE ASSEMBLY)
• Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of
replacement: POWER SUPPLY ASSEMBLY)
• Bk Drum_ITB Motor (M02) (Unit of replacement: MOTOR, DC)
• DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER
PCB ASSEMBLY)
• Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER
SUPPLY ASSEMBLY)
[Points to note at work] When checking the harness/cable or connector,
perform the following work.
1. Disconnect and then connect the connector to check that there is no
bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
[Remedy] It is highly possible that the Bk Drum_ITB Motor is not rotating
due to overload or an electrical trouble. Perform the following in the order
while checking whether the error is cleared.
1. Check whether the gears of the Main Drive Unit can be rotated by hand.
a. If they cannot be rotated, replace the Main Drive Unit.
b. If they can be rotated, check the harnesses from the Bk Drum_ITB
Motor to the DC Controller PCB.
2. Measure the both ends of the fuse in the Low-voltage Power Supply
PCB using a tester.
a. If power is flowing to it (the measurement value is less than 1
ohm),
1. Replace the Bk Drum_ITB Motor.
2. Replace the DC Controller PCB.
b. If the power is not flowing to it (the measurement value is 1 ohm or
higher), replace the Low-voltage Power Supply PCB.
Error
code
Detail
Code
Item
Description
E010 0003 Title
Bk Drum_ITB Motor error
Description There was no FG signal input for 300 msec from the startup of the Bk
Drum_ITB Motor in the Main Drive Unit.
Remedy
[Related parts]
• Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY)
• Harnesses connecting the Bk Drum_ITB Motor (M02/J5702), the
Relay Connector (8P) and the DC Controller PCB (UN04/J140) (Unit of
replacement: MAIN DRIVE ASSEMBLY)
• Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of
replacement: POWER SUPPLY ASSEMBLY)
• Bk Drum_ITB Motor (M02) (Unit of replacement: MOTOR, DC)
• DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER
PCB ASSEMBLY)
• Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER
SUPPLY ASSEMBLY)
[Points to note at work] When checking the harness/cable or connector,
perform the following work.
1. Disconnect and then connect the connector to check that there is no
bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
[Remedy] It is highly possible that the Bk Drum_ITB Motor is not rotating
due to overload or an electrical trouble. Perform the following in the order
while checking whether the error is cleared.
1. Check whether the gears of the Main Drive Unit can be rotated by hand.
a. If they cannot be rotated, replace the Main Drive Unit.
b. If they can be rotated, check the harnesses from the Bk Drum_ITB
Motor to the DC Controller PCB.
2. Measure the both ends of the fuse in the Low-voltage Power Supply
PCB using a tester.
a. If power is flowing to it (the measurement value is less than 1
ohm),
1. Replace the Bk Drum_ITB Motor.
2. Replace the DC Controller PCB.
b. If the power is not flowing to it (the measurement value is 1 ohm or
higher), replace the Low-voltage Power Supply PCB.
Summary of Contents for imageRUNNER C1325 Series
Page 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Page 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...