![Canon imageRUNNER C1325 Series Service Manual Download Page 568](http://html.mh-extra.com/html/canon/imagerunner-c1325-series/imagerunner-c1325-series_service-manual_57874568.webp)
8
8
8-129
8-129
Service Mode > TESTMODE > PRINT
Service Mode > TESTMODE > PRINT
TESTMODE
TESTMODE > PRINT
START
Output of test print
Details
To output a test print with the PG pattern set in PG-TYPE, MODE,
etc.
Use case
At trouble analysis
Adj/set/operate method Press Start key.
PG-TYPE
Setting of PG number
Details
To set the PG number of the test print.
Use case
At trouble analysis
Adj/set/operate method Enter the setting value, and then press Start key.
Display/adj/set range
0: Full correction chart 1
1: Full correction chart 2
2: Color chart
3: Color displacement correction chart
4: Rainbow chart (vertical scanning direction)
5: Rainbow chart (horizontal scanning direction)
6: Grid Bk
12: Full half-tone
Default value
0
COUNT
Setting of PG output quantity
Details
To set the number of sheets for PG output.
Use case
At trouble analysis
Adj/set/operate method Enter the setting value, and then press Start key.
Display/adj/set range
1 to 99
Unit
1 sheet
Default value
1
PHASE
Setting of PG 2-sided mode
Details
To set 1-sided/2-sided print for PG output.
Even if 2-sided print is set for a machine that only supports 1-sided
print, the setting is disabled.
Use case
At trouble analysis
Adj/set/operate method Enter the setting value, and then press Start key.
Display/adj/set range
0 to 1
0: 1-sided, 1: 2-sided
Default value
0
TESTMODE > PRINT
MODE
Setting of test print image formation method
Details
To set the image formation method for the test print.
If PG-TYPE is 0/1, this setting is disabled because a specific image
formation method is applied.
Use case
At trouble analysis
Adj/set/operate method Enter the setting value, and then press Start key.
Display/adj/set range
0 to 3
0: T-MIC (T-MIC), 1: High screen ruling (SCA), 2: Low screen ruling
(SCB), 3: TBIC
Default value
0
THRU
Setting of image correction table at test print
Details
It is possible to check the density characteristics due to the density
correction process when normal gamma LUT is used, and the
density characteristics of the engine when the linear gamma LUT is
used.
Use case
At trouble analysis
Adj/set/operate method Enter the setting value, and then press Start key.
Display/adj/set range
0 to 1
0: Normal gamma LUT, 1: Through (linear) gamma LUT
Default value
0
Supplement/memo
Gamma LUT: Density gradation characteristic table
NRKE
ON/OFF of laser scanning transfer process of test print
Details
To perform line transfer process for skew correction of test print
engine's laser scanning.
Use case
At trouble analysis
Adj/set/operate method Enter the setting value, and then press Start key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Supplement/memo
Transfer process: A process to correct skew of laser scanning in
vertical scanning direction
BLND
ON/OFF of interpolation process at test print
Details
To set ON/OFF of interpolation process at test print (linked with
NSC).
When 1 is set, interpolation process is performed (no phase shift).
Use case
At trouble analysis
Adj/set/operate method Enter the setting value, and then press Start key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Supplement/memo
Interpolation process: A process to predict, for pixels holding no color
information, color based on the surrounding pixels, and then set up
the color information.
Summary of Contents for imageRUNNER C1325 Series
Page 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Page 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...