![Canon imageRUNNER C1325 Series Service Manual Download Page 147](http://html.mh-extra.com/html/canon/imagerunner-c1325-series/imagerunner-c1325-series_service-manual_57874147.webp)
2
2
2-116
2-116
Technical Explanation > Embedded RDS > Error code and strings
Technical Explanation > Embedded RDS > Error code and strings
No.
Code
Cause
Remedy
25 8xxx 2015 Could not connect to proxy server due to
name resolution error of proxy address.
• Check that the proxy server name is
correct. If the proxy server name is
correct, check the DNS connection, as
per the initial procedures described in
the troubleshooting.
• Specify the IP address as the proxy
server name.
26 8xxx 201E Proxy authentication is failed.
Check the user name and password
required in order to login to the proxy,
and re-enter as needed.
27 8xxx 2028 • No route certificate installed in device.
• Certificate other than that initially
registered in the user's operating
environment is being used, but has
not been registered with the device.
• The date and time of the device is not
correct.
• Install the latest device system
software. (Upgrade)
• Correctly set the date and time of the
device.
28 8xxx 2029 The server certificate verification error
occurred.
Contact help desk.
29 8xxx 2046 • The route certificate registered with
the device has expired.
• Certificate other than that initially
registered in the user’s operating
environment is being used, but has
not been registered with the device.
• The device time and date is outside of
the certificated period.
Check that the device time and date are
correctly set.
If the device time and date are correct,
upgrade to the latest system software.
30 8xxx 2047 Due to network congestion, etc., the
response from UGW does not come
within the specified time. (HTTPS level
time out)
If this error occurs when the
communication test is being run or
Service Browser is being set, try again
after a period of time.
31 8xxx 2048 There is a mistake in the UGW URL,
and UGW cannot be accessed. (Path is
wrong)
Contact help desk.
32 8xxx 2052 The data which is not URL is inputted
into URL field.
Contact help desk.
33 8xxx 2058 SOAP Client fails to obtain SOAP
Response.
Possibility of a problem in UGW or of a
temporary problem in the network load.
Perform and complete a communication
test (COM-TEST).
34 8xxx 2063 SOAP communication error has
occurred.
Check that the value of port number of
UGW (RGW-PORT) is 443.
35 xxxx xxxx
An internal error, such as memory
unavailable, etc., has occurred during a
device internal error phase.
Turn the device OFF/ ON.
Or replace the device system software.
(Upgrade)
36 xxxx xxxx
Internal error occurred at the initiating
E-RDS.
Turn the device OFF/ ON.
T-2-58
Summary of Contents for imageRUNNER C1325 Series
Page 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Page 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...