Service Mode > COPIER > ADJUST > CCD
Service Mode > COPIER > ADJUST > CCD
COPIER> ADJUST> CCD
MTF-M4
MTF value 4 setting: horz scan [DADF]
Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
• When replacing the Scanner Unit
• When replacing the Main Controller PCB/clearing the Reader-related
RAM data
Adj/set/operate method 1) Enter the setting value and press Start key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the service
label.
Display/adj/set range
0 to 100
Unit
1 %
Default value
100
MTF-M5
MTF value 5 setting: horz scan [DADF]
Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
• When replacing the Scanner Unit
• When replacing the Main Controller PCB/clearing the Reader-related
RAM data
Adj/set/operate method 1) Enter the setting value and press Start key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the service
label.
Display/adj/set range
0 to 100
Unit
1 %
Default value
100
MTF-M6
MTF value 6 setting: horz scan [DADF]
Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
• When replacing the Scanner Unit
• When replacing the Main Controller PCB/clearing the Reader-related
RAM data
Adj/set/operate method 1) Enter the setting value and press Start key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the service
label.
Display/adj/set range
0 to 100
Unit
1 %
Default value
100
COPIER> ADJUST> CCD
MTF-M7
MTF value 7 setting: horz scan [DADF]
Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
• When replacing the Scanner Unit
• When replacing the Main Controller PCB/clearing the Reader-related
RAM data
Adj/set/operate method 1) Enter the setting value and press Start key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the service
label.
Display/adj/set range
0 to 100
Unit
1 %
Default value
100
MTF-M8
MTF value 8 setting: horz scan [DADF]
Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
• When replacing the Scanner Unit
• When replacing the Main Controller PCB/clearing the Reader-related
RAM data
Adj/set/operate method 1) Enter the setting value and press Start key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the service
label.
Display/adj/set range
0 to 100
Unit
1 %
Default value
100
MTF-M9
MTF value 9 setting: horz scan [DADF]
Details
Setting value for MTF filter coefficient calculation.
Enter the value of service label on the Reader.
Use case
• When replacing the Scanner Unit
• When replacing the Main Controller PCB/clearing the Reader-related
RAM data
Adj/set/operate method 1) Enter the setting value and press Start key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, write the changed value in the service
label.
Display/adj/set range
0 to 100
Unit
1 %
Default value
100
Summary of Contents for imageRUNNER C1325 Series
Page 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Page 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...