8
8
8-107
8-107
Service Mode > COPIER > OPTION > ACC
Service Mode > COPIER > OPTION > ACC
■
ACC
COPIER> OPTION> ACC
CARD-SW
Screen set when Coin Manager connected
Details
To set coin or card that the user is urged to insert on the Control Panel
when the Coin Manager is connected.
Use case
Upon user’s request
Adj/set/operate method 1) Enter the setting value, and then press Start key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 3
0: Coin,
1: Card,
2: Coin and card
3: Card (for customization)
Default value
0
CC-SPSW
Support setting of control card I/F
Details
To set support level for control card (CCIV/CCV) interface.
To keep processing performance of printer engine, select “1: Priority on
speed”.
To correctly stop the output by the upper limit number of sheets, select
“2: Priority on upper limit number of sheets”.
Use case
Upon user’s request (when connecting to the external counter
management system using the control card interface)
Adj/set/operate method 1) Enter the setting value, and then press Start key.
2) Turn OFF/ON the main power switch.
Caution
With priority on speed, output cannot be correctly stopped by the upper
limit number of sheets.
With priority on the upper limit number of sheets, processing
performance of the printer engine is decreased depending on pickup
location.
Display/adj/set range
0 to 2
0: No support
1: Priority on speed
2: Priority on upper limit number of sheets
Default value
0
UNIF-OF
Switching to forcibly turn OFF uniFLOW function
Details
If setting this switch to 1, and turning OFF and then ON the device
power while the uniFLOW function is in active state, the uniFLOW
function is forcibly deactivated.
In addition, when this switch is set to 1, Activate/Deactivate request
from the server is ignored.
Adj/set/operate method 1) Enter the setting value, and then press Start key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Disabled , 1 Enabled
Default value
0
COPIER> OPTION> ACC
OPCST-BA
Set Cst Pedestal not connect error stop
Details
To set whether to stop the error that occurs when the Cassette Pedestal
has not yet been connected.
When 1 is set, the error does not occur even though operation check is
performed only for the host machine.
Use case
When performing operation check for the host machine with no option
cassette connected at the time of installation
Adj/set/operate method Enter the setting value, and then press Start key.
Caution
Be sure to return the value to 0 before the machine is used by the user.
Display/adj/set range
0 to 1
0: Normal, 1: Error not displayed
Default value
0
T-8-47
Summary of Contents for imageRUNNER C1325 Series
Page 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Page 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...