8
8
8-17
8-17
Service Mode > COPIER > DISPLAY > HT-C
Service Mode > COPIER > DISPLAY > HT-C
COPIER> DISPLAY> HT-C
SUM-B-K
Dspl ARCDAT screen B Bk-clr ctrl differ
Details
To display Bk-patch control difference of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-C-Y
Dspl ARCDAT screen C Y-color ctrl differ
Details
To display Y-patch control difference of screen C in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-C-M
Dspl ARCDAT screen C M-color ctrl differ
Details
To display M-patch control difference of screen C in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-C-C
Dspl ARCDAT screen C C-color ctrl differ
Details
To display C-patch control difference of screen C in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-C-K
Dspl ARCDAT screen C Bk-clr ctrl differ
Details
To display Bk-patch control difference of screen C in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
COPIER> DISPLAY> HT-C
SGNL-A-Y
Dspl ARCDAT screen A Y-patch current VL
Details
To display the current Y-patch value of screen A in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-A-M
Dspl ARCDAT screen A M-patch current VL
Details
To display the current M-patch value of screen A in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-A-C
Dspl ARCDAT screen A C-patch current VL
Details
To display the current C-patch value of screen A in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-A-K
Dspl ARCDAT screen A Bk-patch current VL
Details
To display the current Bk-patch value of screen A in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-B-Y
Dspl ARCDAT screen B Y-patch current VL
Details
To display the current Y-patch value of screen B in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
SGNL-B-M
Dspl ARCDAT screen B M-patch current VL
Details
To display the current M-patch value of screen B in ARCDAT control.
When hue variation occurs or the value shown is not in the tolerable
range, check the Patch Sensor or replace the developer.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Summary of Contents for imageRUNNER C1325 Series
Page 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Page 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...