8
8
8-15
8-15
Service Mode > COPIER > DISPLAY > HT-C
Service Mode > COPIER > DISPLAY > HT-C
■
HT-C
COPIER> DISPLAY> HT-C
TGT-A-Y
Dspl ARCDAT screen A Y-color target VL
Details
To display the Y-patch target value of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the target
value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-A-M
Dspl ARCDAT screen A M-color target VL
Details
To display the M-patch target value of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the target
value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-A-C
Dspl ARCDAT screen A C-color target VL
Details
To display the C-patch target value of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the target
value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-A-K
Dspl of ARCDAT screen A Bk-clr target VL
Details
To display the Bk-patch target value of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the target
value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
COPIER> DISPLAY> HT-C
TGT-B-Y
Dspl ARCDAT screen B Y-color target VL
Details
To display the Y-patch target value of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the target
value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-B-M
Dspl ARCDAT screen B M-color target VL
Details
To display the M-patch target value of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the target
value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-B-C
Dspl ARCDAT screen B C-color target VL
Details
To display the C-patch target value of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the target
value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-B-K
Dspl of ARCDAT screen B Bk-clr target VL
Details
To display the Bk-patch target value of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the target
value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
TGT-C-Y
Dspl ARCDAT screen C Y-color target VL
Details
To display the Y-patch target value of screen C in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset the target
value). Check the Patch Sensor if not corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 0 - 700
Summary of Contents for imageRUNNER C1325 Series
Page 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Page 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...