Chapter 5
5-10
5.3.1.3 Adjusting the Sensor Intensity
0015-2224
Go through the following steps when installing the
finisher or replacing specific sensor:
1) Turn on the finisher and the host machine in
sequence.
2) Open the front cover, and insert the door switch
actuator into the door switch [1].
F-5-21
3) Insert a screwdriver [2] through the hole [1] in the
bottom face of the tray; then, disengage the tray in
the direction of [A], and lower the tray A/B in the
direction of [B].
F-5-22
Be sure to lower the tray A/B [2] until it does not
block the tray sensor (front/rear) [1].
F-5-23
4) Detach the inside cover (lower) and the switch
cover [1].
- 1 screw [2]
F-5-24
[1]
[1]
[A]
[B]
[2]
[1]
[2]
[2]
[1]
[2]
[1]
Summary of Contents for Finisher-AB1
Page 9: ...Chapter 1 SPECIFICATIONS ...
Page 16: ...Chapter 2 INSTALLATION ...
Page 33: ...FUNCTIONS Chapter 3 ...
Page 71: ...PARTS REPLACEMENT PROCEDURE Chapter 4 ...
Page 104: ...MAINTENANCE Chapter 5 ...
Page 170: ...Chapter 5 5 64 5 5 3 Solenoids Finisher Unit 0015 2251 F 5 185 SL3 SL2 SL1 SL4 SL5 SL6 SL8 ...
Page 179: ...ERROR CODE Chapter 6 ...
Page 192: ...APPENDIX ...
Page 202: ......
Page 212: ...Chapter 1 SPECIFICATIONS ...
Page 220: ...Chapter 2 INSTALLATION ...
Page 237: ...FUNCTIONS Chapter 3 ...
Page 239: ...Contents 3 8 1 Overview 3 51 3 8 2 Protective Mechanism 3 52 ...
Page 292: ...PARTS REPLACEMENT PROCEDURE Chapter 4 ...
Page 346: ...MAINTENANCE Chapter 5 ...
Page 422: ...Chapter 5 5 74 5 5 3 Solenoids Finisher Unit 0015 2251 F 5 216 SL3 SL2 SL1 SL4 SL5 SL6 SL8 ...
Page 438: ...ERROR CODE Chapter 6 ...
Page 451: ...APPENDIX ...
Page 463: ......