Chapter 5
5-27
10) If A (between 1st and 2nd sheets) or B (between
2nd and 3rd sheets) is not as indicated, go through
the following:
Press the push switch SW385 [1] so that the
machine is in adjustment mode for A (between 1st
and 2nd sheets). Press the push switch SW383 [2]
to decrease the displacement, or press SW384 [3]
to increase the displacement. (The LED [4]
indicates the correction value.)
range of adjustment: +30 to -30 (unit: 0.2 mm)
F-5-84
11) If B (between 2nd and 3rd sheets) is not as
indicated, go through the following:
Press the push switch SW385 [1] so that the
machine is in adjustment mode for B (between 1st
and 3rd sheets).
Press the push switch SW382 [2] to decrease
the displacement, or press SW384 [3] to increase
the displacement. (The LED [4] will indicate the
correction value.)
range of adjustment: +30 to -30 (unit: 0.2 mm)
Another press on SW385 will store the A/B
correction value.
F-5-85
A press on the push switch SW385 while the LED is
indicating '0' will cause the LED to indicate the A
and B correction values in sequence.
Pay attention so that you remain aware of which
correction value you are working on.
5.3.2.11 Adjustment of EEPROM (IC107)
on the Finisher Controller PCB After
Replacement
0015-2244
Adjustments after replacing the EEPROM (IC107)
on the finisher controller PCB
These adjustments are performed when the
EEPROM (IC107) on the finisher controller PCB
has been replaced.
1) Turn on the finisher.
2) Turn on the copier and set the copier in a stand-by
mode.
3) Open the front door, and insert the door switch
actuator into the door switch [1].
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
[2]
[3]
[4]
[1]
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
[2]
[3]
[4]
[1]
Summary of Contents for Finisher-AB1
Page 9: ...Chapter 1 SPECIFICATIONS ...
Page 16: ...Chapter 2 INSTALLATION ...
Page 33: ...FUNCTIONS Chapter 3 ...
Page 71: ...PARTS REPLACEMENT PROCEDURE Chapter 4 ...
Page 104: ...MAINTENANCE Chapter 5 ...
Page 170: ...Chapter 5 5 64 5 5 3 Solenoids Finisher Unit 0015 2251 F 5 185 SL3 SL2 SL1 SL4 SL5 SL6 SL8 ...
Page 179: ...ERROR CODE Chapter 6 ...
Page 192: ...APPENDIX ...
Page 202: ......
Page 212: ...Chapter 1 SPECIFICATIONS ...
Page 220: ...Chapter 2 INSTALLATION ...
Page 237: ...FUNCTIONS Chapter 3 ...
Page 239: ...Contents 3 8 1 Overview 3 51 3 8 2 Protective Mechanism 3 52 ...
Page 292: ...PARTS REPLACEMENT PROCEDURE Chapter 4 ...
Page 346: ...MAINTENANCE Chapter 5 ...
Page 422: ...Chapter 5 5 74 5 5 3 Solenoids Finisher Unit 0015 2251 F 5 216 SL3 SL2 SL1 SL4 SL5 SL6 SL8 ...
Page 438: ...ERROR CODE Chapter 6 ...
Page 451: ...APPENDIX ...
Page 463: ......