Chapter 5
5-22
10) Check to make sure that the stapling position is 5
+/-2 mm [1] as a result of the foregoing steps.
Otherwise, go back to step 6).
F-5-68
If the LED indicates other than '0', the adjustment is
likely to have failed. Start over.
5.3.2.9 Adjusting the Stapling Position (2-
point)
0015-2237
Go through the following steps if there is
displacement in stapling position (2-point) or if you
have replaced the EEPROM of the finisher controller
PCB:
1) Turn on the finisher.
2) Turn on the host machine so that it will be in a
standby state.
3) Open the front door, and insert the door switch
actuator into the door switch [1].
F-5-69
4) Remove the screw [2], and detach the switch
cover [1].
F-5-70
[1]
[1]
[2]
[1]
Summary of Contents for Finisher-AB1
Page 9: ...Chapter 1 SPECIFICATIONS ...
Page 16: ...Chapter 2 INSTALLATION ...
Page 33: ...FUNCTIONS Chapter 3 ...
Page 71: ...PARTS REPLACEMENT PROCEDURE Chapter 4 ...
Page 104: ...MAINTENANCE Chapter 5 ...
Page 170: ...Chapter 5 5 64 5 5 3 Solenoids Finisher Unit 0015 2251 F 5 185 SL3 SL2 SL1 SL4 SL5 SL6 SL8 ...
Page 179: ...ERROR CODE Chapter 6 ...
Page 192: ...APPENDIX ...
Page 202: ......
Page 212: ...Chapter 1 SPECIFICATIONS ...
Page 220: ...Chapter 2 INSTALLATION ...
Page 237: ...FUNCTIONS Chapter 3 ...
Page 239: ...Contents 3 8 1 Overview 3 51 3 8 2 Protective Mechanism 3 52 ...
Page 292: ...PARTS REPLACEMENT PROCEDURE Chapter 4 ...
Page 346: ...MAINTENANCE Chapter 5 ...
Page 422: ...Chapter 5 5 74 5 5 3 Solenoids Finisher Unit 0015 2251 F 5 216 SL3 SL2 SL1 SL4 SL5 SL6 SL8 ...
Page 438: ...ERROR CODE Chapter 6 ...
Page 451: ...APPENDIX ...
Page 463: ......