86
cab Produkttechnik GmbH & Co KG
A3-2 / A3 / A4 / A6
9. Test Options
Test Grid
The "Test grid" option generates a printout that prints a test grid that allows the
operator or service technician to evaluate and check the quality of the printed
image.
To get a printout of the test grid, load media (labels, continuous paper) and a
transfer ribbon (if applicable), which extends over the entire print width of the
printer.
1. Switch from "Online" mode to the Offline Menu by pressing the
key.
2. Press the key or the key until the "Test" menu is displayed.
Press the key to confirm the selection.
3. Select the option "Test grid" by pressing the key or the key and
confirm the selection by pressing the key.
4. Start the printout by pressing the key.
5. The pattern shown in figure 9s will be printed. The printout will repeat about
every 5 seconds making it possible to make adjustments on the printer
between the individual printouts.
6. The "Test grid" printout will be printed with the heat level and print speed set
in the "Setup" menu.
7. The "Test grid" printout can be canceled by pressing the
key. Once
the printout has been canceled, the printer returns to the selection list of the
"Test" menu.