5 - 31
CNC AXIS MODULES
Edition 06.2005
5.4
Digital axis module SERC (continuation)
Status-
Meaning of the error messages
display
P
False phase specification of the numerical control
The NC as SERCOS phase a target phase gave not equal to 0, 1, 2, 3 or 4.
Reaction by SERC
Phase resetting in communication phase 0.
A cause
In the parameter, phase specification “ (Y-0-0014) became a target phase not equal 0, 1,
2, 3 or 4 given and in more lnterruptsteuerregister the instruction, “phase modifies “
(value 0x2000) released.
Remedial action
Parameters, phase specification “ (Y-0-0014) phase specification with valid value describe.