I-Modell - 11/12 - Ausgabe 09/11 - 2096165 - BUE-0056-05EN
Troubleshooting
14
No 230 V power supply
despite connection
230 V automatic circuit
breaker has triggered
Switch on the 230 V au-
tomatic circuit breaker
The mains connection is
de-energised
Check the mains connec-
tion
Starter or living area bat-
tery is not charged when
operated in 230 V mode
Jumbo flat fuse (50 A) on
the starter or living area
battery is defective
Replace jumbo flat fuse
(50 A) on the starter or
living area battery
Charger module in the
transformer/rectifier is
defective
Contact customer service
Living area battery is not
charged during vehicle
operation
Fuse on terminal D+ of
the alternator is defective
Replace fuse
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
12 V power supply does
not work
12 V power supply
switched off
Switch 12 V power sup-
ply on
Battery cut-off switch on
the transformer/rectifier
switched off or battery
separation activated
Switch on battery cut-off
switch or deactivate bat-
tery separation via the
panel
Living area battery is dis-
charged
Charging the living area
battery
Jumbo flat fuse (50 A) on
the living area battery is
defective
Replace jumbo flat fuse
(50 A) on the living area
battery
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
12 V power supply does
not work in 230 V opera-
tion
12 V power supply
switched off
Switch 12 V power sup-
ply on
Battery cut-off switch on
the transformer/rectifier
switched off or battery
separation activated
Switch on battery cut-off
switch or deactivate bat-
tery separation via the
panel
Charger module in the
transformer/rectifier is
defective
Contact customer service
230 V automatic circuit
breaker has triggered
Contact customer service
Jumbo flat fuse (50 A) on
the living area battery is
defective
Replace jumbo flat fuse
(50 A) on the living area
battery
Starter battery is dis-
charged in 12 V opera-
tion
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
Battery cut-off switch on
the transformer/rectifier
switched off or battery
separation activated
Switch on battery cut-off
switch or deactivate bat-
tery separation via the
panel
Fault
Cause
Remedy
Summary of Contents for I 2012
Page 2: ...I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Instruction manual...
Page 8: ...Contents 8 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN...
Page 48: ...48 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN During the journey 4...
Page 106: ...106 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Gas system 7...
Page 180: ...180 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Appliances 9...
Page 214: ...214 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Care 11...
Page 242: ...242 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Wheels and tyres 13...
Page 258: ...258 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Special equipment 15...
Page 266: ...266 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Technical data 16...
Page 278: ...278 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN Helpful notes 17...
Page 292: ...Index 292 I Modell 11 12 Ausgabe 09 11 2096165 BUE 0056 05EN...