208
I-Modell - 07/07 - Ausgabe 03/07 - 1512317 - BUE-0056-00EN
Technical data
16
Charging current
16 A throughout entire sup-
ply voltage range, electroni-
cally restricted
16 A
Trickle charge voltage
Automatic switching
13.8 V
Repeated charging cycle
(switchover to "Main charg-
ing")
At < approx. 13.8 V battery
voltage (with approx.
5 seconds delay)
Reflux (without mains and
with connected battery)
After approx. 3 minutes
"Mains Off"
< 0.3 mA
Guard circuits
Short-circuit protection pro-
vided by built-in car fuse
(FKS)
Safety fuse, 2.5 AT at pow-
er input
Overtemperature protection
Charging current distribu-
tion at mains connection
Starter battery float charge
with max. 2 A
Max. 2 A
Living area battery charge
with max. 16 A
Max. 16 A
Charging current distribu-
tion during the journey
Simultaneous charging of
starter and living area bat-
teries by means of the alter-
nator
50 A
Parallel battery switching
via disconnector relay
Maximum permitted alter-
nator charging current to
the living area battery: 50 A
(see block diagram)
Battery monitor
Disconnection
10.6 V ± 0.1 V
Battery monitor
Minimum voltage for con-
nection
11.0 V ± 0.1 V
Summary of Contents for Goldie
Page 2: ...I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Instruction manual...
Page 30: ...30 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Before the journey 3...
Page 74: ...74 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Living 6...
Page 82: ...82 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Gas system 7...
Page 160: ...160 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Sanitary fittings 10...
Page 168: ...168 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Care 11...
Page 182: ...182 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Maintenance 12...