Alde hot-water heater (special equipment)
The hot-water heater has been fitted below in the wardrobe.
Operating modes
The hot-water heater has two operating modes:
Heater and hot water (Fig. 117,4)
Hot water (Fig. 117,2)
Selecting operating mode:
Use the sliding switch (Fig. 117,3) to set the operating mode.
The hot-water heater can be operated with the following energy sources:
Gas operation (Fig. 117,5)
230 V electrical operation (Fig. 117,7)
Gas and 230 V electrical operation
Gas operation
Switching on:
Open the regulator tap on the gas bottle and the gas isolator tap "Heater/
boiler".
Set sliding switch (Fig. 117,5) to gas operation.
Turn the temperature control knob (Fig. 117,1) on the operating unit to the
desired heating level.
Set sliding switch (Fig. 117,3) to either "Heater and hot water" (Fig. 117,4)
or to "Hot water" (Fig. 117,2).
The red indicator lamp (Fig. 117,6) goes on whenever a fault occurs.
Switching off:
Set the sliding switches (Fig. 117,3 and 5) to "0".
Close the gas isolator tap "Heater/boiler" and the regulator tap on the gas
bottle.
Never run hot-water heater without heating fluid. Observe notes in
chapter 12.
Never drill holes in the floor. This might damage the hot-water pipes.
Do not use the space above and behind the heater as a storage compart-
ment.
Bürstner recommends to bleed the heating system after the initial heater
operation and to check the glycol content. Observe notes in chapter 12.
For further information, see the separate instruction manual "Alde Com-
pact" and observe the maintenance instructions found in chapter 12.
For further information about the use of the boiler see section "Boiler".
Fig. 117 Operating unit for hot-water
heater
1
Temperature control knob
2
Operating mode "Hot water"
3
Sliding switch for circulating pump
4
Operating mode "Heater and hot
water"
5
Sliding switch for gas operation
6
Red indicator lamp "Fault"
7
Sliding switch for 230 V electrical
operation
Summary of Contents for Goldie
Page 2: ...I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Instruction manual...
Page 30: ...30 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Before the journey 3...
Page 74: ...74 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Living 6...
Page 82: ...82 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Gas system 7...
Page 160: ...160 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Sanitary fittings 10...
Page 168: ...168 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Care 11...
Page 182: ...182 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Maintenance 12...