195
I-Modell - 07/07 - Ausgabe 03/07 - 1512317 - BUE-0056-00EN
Troubleshooting
14
14.5.1
Trumatic C heater/boiler
Fault
Cause
Remedy
Heating does not ignite
Temperature sense on
operating unit or remote
sensor defective
Pull out plug on operating
unit. The heating then
works without thermostat.
Contact the customer
service as soon as possi-
ble
Red indicator lamp
"Fault" illuminates
Air in the gas pipe sys-
tem
Switch off and on again.
After two futile ignition at-
tempts, wait for
10 minutes before trying
again
Lack of gas
Open regulator tap and
gas isolator tap
Connect a full gas bottle
Defect of a safety ele-
ment
Contact customer service
Red indicator lamp
"Fault" is flashing
Operating voltage too low
Charge or replace the liv-
ing area battery (or have
it charged or replaced)
Green indicator lamp be-
hind knob is not lit
Fuse on the transformer/
rectifier is defective
Replace fuse on the
transformer/rectifier
Fuse in the electronic
control unit has been trig-
gered
Contact customer service
Living area battery defec-
tive
Charge or replace the liv-
ing area battery (or have
it charged or replaced)
Yellow indicator lamp on
the energy selector
switch does not illumi-
nate
No supply voltage
Check 230 V connection
and fuses
Overheating switch was
triggered
Press overheating switch
Boiler empties, safety/
drainage valve has
opened
Internal temperature be-
low 8 °C
Heat inside
Battery cut-off switch on
the transformer/rectifier is
switched off
Set battery cut-off switch
to on
Operating voltage below
10.8 V
Charge or replace the liv-
ing area battery (or have
it charged or replaced)
Fuse is defective
Replace fuse on the
transformer/rectifier
Summary of Contents for Goldie
Page 2: ...I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Instruction manual...
Page 30: ...30 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Before the journey 3...
Page 74: ...74 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Living 6...
Page 82: ...82 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Gas system 7...
Page 160: ...160 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Sanitary fittings 10...
Page 168: ...168 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Care 11...
Page 182: ...182 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Maintenance 12...