193
I-Modell - 07/07 - Ausgabe 03/07 - 1512317 - BUE-0056-00EN
Troubleshooting
14
14.3
Gas system
No voltage is supplied by
the living area battery
The living area battery is
discharged
Charge living area bat-
tery immediately
Total discharge
damages the
battery.
If the vehicle is to be laid
up for a long period, fully
charge the living area
battery beforehand
Discharging is caused by
inactive appliances (see
chapter 8)
12 V indicator lamp does
not light up or there is no
display
12 V power supply
switched off
Switch 12 V power sup-
ply on
Battery cut-off switch on
the transformer/rectifier is
switched off
Set battery cut-off switch
to on
Starter or living area bat-
tery is not charged
Charge the starter or liv-
ing area battery
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
Flat fuse (2 A) in the liv-
ing area battery is defec-
tive
Replace flat fuse (2 A) in
the living area battery
Extractor hood does not
work
230 V automatic circuit
breaker is switched off
Switch on the 230 V au-
tomatic circuit breaker
Fuse (15 A) at the trans-
former/rectifier is defec-
tive
Replace fuse (15 A)
Extractor hood defective
Contact customer service
Air conditioning unit can-
not be switched on or off
230 V automatic circuit
breaker has triggered
Switch on the 230 V au-
tomatic circuit breaker
Remote control battery is
empty
Change remote control
battery
In case of a defect of the gas system (gas odour, high gas consumption)
there is danger of explosion! Close regulator tap on the gas bottle imme-
diately. Open doors and windows and ventilate well.
If the gas system is defective: Do not smoke; do not ignite any open
flames, and do not operate electric switches (light switches etc.).
Have the defective gas system repaired by an authorised specialist
workshop.
Fault
Cause
Remedy
Summary of Contents for Goldie
Page 2: ...I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Instruction manual...
Page 30: ...30 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Before the journey 3...
Page 74: ...74 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Living 6...
Page 82: ...82 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Gas system 7...
Page 160: ...160 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Sanitary fittings 10...
Page 168: ...168 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Care 11...
Page 182: ...182 I Modell 07 07 Ausgabe 03 07 1512317 BUE 0056 00EN Maintenance 12...