USE THIS CHART FOR VATS, PASSLOCK I & PASSLOCK II
1 - 8-Pin Harness
Dip Switch #
2
3
4
5
6
Resistor Value
0.825
1.65
3.32
6.65
13.3 Final Resistance (k ohms)
ON
ON
ON
ON
ON
0.000 +Trimpot Value
OFF
ON
ON
ON
ON
0.825 +Trimpot Value
ON
OFF
ON
ON
ON
1.650 +Trimpot Value
OFF
OFF
ON
ON
ON
2.475 +Trimpot Value
ON
ON
OFF
ON
ON
3.320 +Trimpot Value
OFF
ON
OFF
ON
ON
4.145 +Trimpot Value
ON
OFF
ON
ON
ON
4.970 +Trimpot Value
OFF
OFF
OFF
ON
ON
5.795 +Trimpot Value
ON
ON
ON
OFF
ON
6.650 +Trimpot Value
OFF
ON
ON
OFF
ON
7.475 +Trimpot Value
ON
OFF
ON
OFF
ON
8.300 +Trimpot Value
OFF
OFF
ON
OFF
ON
9.125 +Trimpot Value
ON
ON
OFF
OFF
ON
9.970 +Trimpot Value
OFF
ON
OFF
OFF
ON
10.795 +Trimpot Value
ON
OFF
OFF
OFF
ON
11.620 +Trimpot Value
OFF
OFF
OFF
OFF
ON
12.445 +Trimpot Value
ON
ON
ON
ON
OFF 13.300 +Trimpot Value
OFF
ON
ON
ON
OFF 14.125 +Trimpot Value
ON
OFF
ON
ON
OFF 14.950 +Trimpot Value
OFF
OFF
ON
ON
OFF 15.775 +Trimpot Value
ON
ON
OFF
ON
OFF 16.620 +Trimpot Value
OFF
ON
OFF
ON
OFF 17.445 +Trimpot Value
ON
OFF
OFF
ON
OFF 18.270 +Trimpot Value
OFF
OFF
OFF
ON
OFF 19.095 +Trimpot Value
ON
ON
ON
OFF
OFF 19.950 +Trimpot Value
OFF
ON
ON
OFF
OFF 20.775 +Trimpot Value
ON
OFF
ON
OFF
OFF 21.600 +Trimpot Value
OFF
OFF
ON
OFF
OFF 22.425 +Trimpot Value
ON
ON
OFF
OFF
OFF 23.270 +Trimpot Value
OFF
ON
OFF
OFF
OFF 24.095 +Trimpot Value
ON
OFF
OFF
OFF
OFF 24.920 +Trimpot Value
OFF
OFF
OFF
OFF
OFF 25.745 +Trimpot Value
All resistor values shown are in ‘K-Ohms’ or 1,000 Ohms. Thus the 1.650 value shown in
the (3) Third row is 1,650 Ohms or 1.65K Ohms.
Dip Switch #1
Dip Switch #7
VATS
OFF
OFF
PASSLOCK I
ON
ON
PASSLOCK II
OFF
OFF
WIRING CONNECTIONS
H4/5 - RED/WHITE wire - (-) 200mA Channel 3 (Trunk) Output
This wire is a 1 Second pulsed Ground or (-) Negative Output that
can be use to operate the Electric Truck Release on a vehicle. If
the Trunk Release is a (-) Negative that is BCM controlled, no extra
parts are required. If the vehicle’s Trunk Release wire is a (+)
Positive or is not BCM Controlled, then an extra Relay Part #775 is
required. See Diagram above.
H4/6 - Brown I Black wire - (-) 2OOmA Factory Security Rearm
Signal / Key Sensor Output -
Factory Security Rearm Signal Output (Factory default setting.)
This output is programmable. If programmed it can rearm a factory
installed security system. This wire will supply a pulse whenever the
remote start times out or is shut down using the transmitter and
remote door locking.
Ground Output During Start Crank)
This wire will provide a 2OOmA ground output while the starter out-
put of the remote start unit is active. This output can be used to ac-
tivate the Crank Low/Bulb Test wire found in some GM vehicles. This
wire is also referred to as the ECM wake up wire in some vehicles.
Summary of Contents for DELUXE 200B