Operation
SMART 200 MTC
-3.3 -
6.
Operator’s message Area:
The menu choices, or settings for the selected function during programming or
setup phase of the system as well as service messages are displayed with large size
fonts
(1,5 x 0,8 cm),
easy to read even from a distance, when the system is running
normally. In other words, it shows all the necessary information to guide the
operator step by step through the programming phase and interactive management
of the system.
When the displayed lines refer to the menu items, the selected one is indicated with
the symbol
>
.
The presence of a flashing cursor
(---)
indicates the position where the operator can
enter an alphanumeric character or variable setting which will replace the value
currently displayed.
When you select the GRAPH function from the main menu, this area of the screen
is used to graphically represent the count progress.
7.
Operating Status Signaling Area
To enable a more direct and evident interpretation of the operating context in
which you are working, on the right hand side of the operator message area, 6
rectangular boxes
(labels)
are implemented. They display the operating status of
the system
More specifically, the
PROGRAM
label indicates that you are operating in one of
the following modes: configuration, programming or data transmission to the
sensors.
The
CONTROL
label indicates that the system is operating normally with all
monitor functions enabled, and according to the settings currently set in the system.
In this phase the message display indicates
CONTROL MTC
.
The
TARGET
label indicates that one or multiple sensors reached the number of
meters setup
( target )
.
The
ERROR
label indicates that an error has been detected during normal
operation of the system. In this case the message display shows the type of error
detected
(for further information please refer to Operations Sequences and to
Chapter 4 “Troubleshooting and Maintenance”).
The labels
P1 .. P5
indicate the hierarchic level of the menu in which you are
operating.
P1
is the highest level,
P5
is the lowest hierarchical level. To move
from an upper to a lower level you must normally press down the
ENTER
button,
while to do the opposite, i.e. going from a lower to an upper level you must press
the
RESET
button.
SMART
200 MTC
Summary of Contents for IS3W/MTC
Page 1: ...SMART 200 MTC IS3W MTC METER CONTROL SYSTEM Operating Manual Rev 2 0 September 2003 ENGLISH ...
Page 14: ...Technical Data and Installation 2 6 SMART 200 MTC Page intentionally left blank ...
Page 26: ...Operation 3 12 SMART 200 MTC Enabling the SETUP Menu Functions ...
Page 28: ...Operation 3 14 SMART 200 MTC Enabling the GRAPH Menu Functions ...
Page 69: ...Operation SMART 200 MTC 3 55 Production Report Example ...
Page 70: ...Operation 3 56 SMART 200 MTC Page intentionally left blank ...
Page 78: ...Appendix A Quick Reference Symbols Key A 2 SMART 200 MTC ...
Page 79: ...Appendix A Quick Reference Symbols Key SMART 200 MTC A 3 ...
Page 80: ...Appendix A Quick Reference Symbols Key A 4 SMART 200 MTC NO NC ...
Page 81: ...Appendix A Quick Reference Symbols Key SMART 200 MTC A 5 ...
Page 82: ...Appendix A Quick Reference Symbols Key A 6 SMART 200 MTC ...
Page 83: ...Appendix A Quick Reference Symbols Key SMART 200 MTC A 7 ...
Page 84: ...Appendix A Quick Reference Symbols Key A 8 SMART 200 MTC ...
Page 85: ...Appendix A Quick Reference Symbols Key SMART 200 MTC A 9 ...
Page 86: ...Appendix A Quick Reference Symbols Key A 10 SMART 200 MTC ...
Page 87: ...Appendix A Quick Reference SMART 200 MTC A 11 Notes ...
Page 88: ...Appendix A Quick Reference A 12 SMART 200 MTC Page intentionally left blank ...