Technical Data and Installation
- 2.4 -
SMART 200 MTC
Connecting Cables and Power Supply Devices
To correctly install the
SMART 200 MTC
system and sensors, it is necessary to
use a certain number of connecting cables provided by
BTSR;
their length and
type depend on the specific requirements and application types.
The following table lists at glance the types and lengths of the main connecting
cables, which
BTSR
may provide. For further details and queries about the cables
and options available, please contact your local dealer.
SMART Power Cables (I/O Connector)
FE10/200
Length 200 cm
FE10/500
Length 500 cm
Cables 4 x 0.35 mm with Female to Female Connector for connections
between SMART 200 MTC /PSU 10A and Doubler cable MA2FE3
FE100/FEC
Length 100 cm
FE200/FEC
Length 200 cm
FE300/FEC
Length 300 cm
FE400/FEC
Length 400 cm
Doubler Cable from one Male to two Female with Independent Stop
and Ground outputs to Connect a Alarm Signaling Light, etc.
MA2FE3
Extension Cable 4x0.35 mm with Male and Female connector.
MA50/FEC
Length 50 cm
MA100/FEC
Length 100 cm
MA200/FEC
Length 200 cm
Connection cable with AMP male connector for single IS3W..
sensor
MA35/CR
Length 35 cm
MA50/CR
Length 50 cm
MA100/CR
Length 100 cm
MA150/CR
Length 150 cm
Transformers for SMART 200 MTC
TRF1524/100
Output 15/24 Vac 100VA
(can be used with up to 40 sensors)
TRF24/300VA
Output 24 Vac/300VA
(can be used with more than 40 sensors)
Stabilized Power Supply with 24 Vdc output, 10A Peak, 6A
continuous
PSU 10A
Required with more than 40 sensors (up to a maximum of 100
sensors for each PSU 10A)
Printer for SMART 200 MTC
PRNT 01
Printer with clock-calendar feature for production report, including
CV485/232
conversion interface cable.
Summary of Contents for IS3W/MTC
Page 1: ...SMART 200 MTC IS3W MTC METER CONTROL SYSTEM Operating Manual Rev 2 0 September 2003 ENGLISH ...
Page 14: ...Technical Data and Installation 2 6 SMART 200 MTC Page intentionally left blank ...
Page 26: ...Operation 3 12 SMART 200 MTC Enabling the SETUP Menu Functions ...
Page 28: ...Operation 3 14 SMART 200 MTC Enabling the GRAPH Menu Functions ...
Page 69: ...Operation SMART 200 MTC 3 55 Production Report Example ...
Page 70: ...Operation 3 56 SMART 200 MTC Page intentionally left blank ...
Page 78: ...Appendix A Quick Reference Symbols Key A 2 SMART 200 MTC ...
Page 79: ...Appendix A Quick Reference Symbols Key SMART 200 MTC A 3 ...
Page 80: ...Appendix A Quick Reference Symbols Key A 4 SMART 200 MTC NO NC ...
Page 81: ...Appendix A Quick Reference Symbols Key SMART 200 MTC A 5 ...
Page 82: ...Appendix A Quick Reference Symbols Key A 6 SMART 200 MTC ...
Page 83: ...Appendix A Quick Reference Symbols Key SMART 200 MTC A 7 ...
Page 84: ...Appendix A Quick Reference Symbols Key A 8 SMART 200 MTC ...
Page 85: ...Appendix A Quick Reference Symbols Key SMART 200 MTC A 9 ...
Page 86: ...Appendix A Quick Reference Symbols Key A 10 SMART 200 MTC ...
Page 87: ...Appendix A Quick Reference SMART 200 MTC A 11 Notes ...
Page 88: ...Appendix A Quick Reference A 12 SMART 200 MTC Page intentionally left blank ...