the drain valve.
17. Screw the vent screw (Fig. 107/3) again
onto the vent opening of the compensating
reservoir (Fig. 107/1).
18. Carry out a test run for several minutes.
19. Check the oil level in the compensating
reservoir afterwards.
20. Fill gear lubricant oil through the vent
opening (Fig. 107/3) into the compensating
reservoir if necessary.
Check the oil level in the mixer
gearbox several times during the
first 10 service hours after
changing the gear lubricant oil.
12.5.4 Switchgear
The gearbox(es) require(s):
check of oil level and topping-up if necessary,
change of gear lubricant oil.
12.5.4.1 Check oil level
1. Remove the inspection plug (1) to check the
oil level.
The oil level must reach the tap hole.
2. Top up oil through the filler neck (2) if
necessary.
3. Screw the inspection plug in again.
Fig. 110