Malfunctions and remedy
Verti-Mix 951-1651, Verti-Mix 951 L-1251 L, Verti-Mix 1501 D-2401 D 10.13
177
13.3
Weighing device
It is absolutely imperative to observe the included operating
instructions for the weighing device.
Malfunction
Cause
Remedy
Device cannot be switched on
No power supply
Check connecting cable.
Switch on power supply, check
power supply battery.
Wrong polarity
Check polarity connecting cable.
(The devices are equipped with
an automatic fuse).
Device displays bars (top or
bottom)
Device
Pull the terminal box plug out of
the weighing computer and watch
display.
If the bars disappear, the
weighing computer functions
properly.
Terminal box
Pull out the plugs of all weighing
rods, the terminal box being
plugged into the weighing
computer. Watch display. If the
bars disappear, the display
functions properly.
Weighing rods
Always plug only one weighing
rod at a time into the terminal box
or directly into the weighing
computer. If the bars disappear,
the respective weighing rod
functions properly.
Weighed value varies
Device
See malfunction description:
"Device displays bars".
Terminal box
See malfunction description:
"Device displays bars".
Weighing rods
See malfunction description:
"Device displays bars".
Scales display wrong weighed
value
Weighing rods not properly
installed
Always plug only one weighing
rod at a time into the terminal box
or directly into the weighing
computer.
The displayed value must
increase when load is applied.
Always test all rods!
Weighing system misadjusted
Readjust scales, see included
operating instructions
"Recalibration".
Device displays ERROR
Internal error
Send device in for repair.
Tab. 17