III - 22
3.4 Write Setting Mode ([1] key):
Required on the Production Line
Be sure to provide power supply of DC12.0V ±0.1V / DC9.0V ±0.1V [Insert resistant
1
Ω
±5% (2W and more)] for the inspection from DC power or AA battery.
3.4.1 Head Rank Set Mode
Press the
[OK]
or
[ENTER]
key at the state of <
>, or press the
[1]
key,
and the LCD displays as shown in <
Figure 3.4-1 Write Head Rank Mode
Press the
[OK]
or
[ENTER]
key to proceed to the display shown in <
The current head rank will be displayed on the right bottom of the LCD.
The indication of the head rank will be changed simultaneously by pressing the
[1]
to
[3]
,
[
]
or
[
]
key while this screen is displayed.
* The head rank is set to "B" by default.
Figure 3.4-2
After setting the head rank to "A", "B" or "C", proceed to "Write Country Set" by
pressing the
[OK]
or
[ENTER]
key.
Current head rank shown on the right bottom of the LCD.
Head rank setting
LCD
A
A
B
B
C
C
HEAD RANK SET